Abstract

BACKGROUND

Patellofemoral joint (PFJ) issues after total knee arthroplasty (TKA) are becoming a topic of interest once again. Due to the complex three-dimensional shape of the trochlea, various two-dimensional proxy measurements on plain X-rays have been described. One of these measurements is the anterior femoral offset (AFO). It is the distance between the anterior femoral cortex and the trochlea's most anterior point (MAP) on a true lateral X-ray after TKA. Because the relationship between the trochlea's MAP and its groove, which is the primary joint surface articulating with the patella, is unknown, the purpose of this study was to measure the distance between the MAP and the trochlear groove.

METHODS

After femoral component implantation, the surgeon identified the trochlea's MAP and the trochlear groove in ten consecutive TKAs and measured their distance. Measurements were performed with a ruler on a true lateral photograph and with a radiographic marker on a lateral radiograph in four different knee flexion angles, according to a previously published protocol.

RESULTS

The trochlear groove had a mean distance from the MAP between 2.09 ± 0.15 and 5.50 ± 0.17 mm, depending on the position. In no case is the trochlear groove visible on a true lateral view.

CONCLUSION

On a true lateral X-ray, the trochlea's MAP omits the trochlear groove. Because the patella primarily articulates with the trochlear groove and because the relationship between the MAP and the trochlear groove is variable depending on the knee flexion angle, any conclusions regarding overstuffing based on a postoperative lateral knee X-ray are flawed.

摘要

背景

全膝关节置换术(TKA)后髌股关节(PFJ)问题再次成为人们关注的话题。由于滑车的三维形状复杂,已有多种在普通X射线上进行的二维替代测量方法被描述。其中一种测量方法是股骨前偏移(AFO)。它是TKA后在真正的侧位X射线上股骨前皮质与滑车最前点(MAP)之间的距离。由于滑车的MAP与其沟(即与髌骨主要关节面相关的沟)之间的关系尚不清楚,本研究的目的是测量MAP与滑车沟之间的距离。

方法

在植入股骨假体后,外科医生在连续的10例TKA中确定滑车的MAP和滑车沟,并测量它们之间的距离。根据先前公布的方案,在四个不同的膝关节屈曲角度下,用尺子在真正的侧位照片上以及用射线标记物在侧位X射线上进行测量。

结果

根据位置不同,滑车沟与MAP之间的平均距离在2.09±0.15至5.50±0.17毫米之间。在真正的侧位视图中,滑车沟均不可见。

结论

在真正的侧位X射线上,滑车的MAP未包含滑车沟。由于髌骨主要与滑车沟相关节,且MAP与滑车沟之间的关系因膝关节屈曲角度而异,基于术后膝关节侧位X射线得出的任何关于填充过度的结论都是有缺陷的。