Wang Jia, Hong Chengyi, Lin Zhengzhong, Huang Zhi-Yong
College of Ocean Food and Biological Engineering, Jimei University, Xiamen, China.
J Food Drug Anal. 2022 Sep 15;30(3):369-381. doi: 10.38212/2224-6614.3422.
A simple fluorescence method to quantitatively monitor malachite green (MG) was introduced based on the conformation switch effect of MG-aptamer (Apt) and the fluorochrome of SYBR Green I (SGI). SGI can embed in the stem-loop structure of Apt to produce fluorescence. However, the fluorescence will be quenched when MG is introduced because of the specific binding of Apt to MG. Under the optimal conditions, the fluorescence method displayed excellent linear relationship between the fluorescence quenching efficiencies and the MG concentrations ranging from 0.02 μmol L to 1.0 μmol L. The detection limit of the method was 0.67 μg kg (3α/κ, n = 9) which is lower than the limit (1 μg kg) specified in the national standard of China (GB/T 19857-2005) and the limit (2 μg kg) specified by the European Food Safety Authority (EFSA, 2016). Excellent recoveries between 87.1% and 106.9% tested by spiking standards were achieved with RSD less than 6.4%. The data were confirmed by the method of HPLC, and the results proved that the established fluorescence method could be used for the rapid detection of MG in fish with high accuracy and sensitivity.
基于孔雀石绿适配体(Apt)与SYBR Green I(SGI)荧光染料的构象转换效应,介绍了一种简单的荧光方法用于定量监测孔雀石绿(MG)。SGI可嵌入Apt的茎环结构中产生荧光。然而,当引入MG时,由于Apt与MG的特异性结合,荧光会被淬灭。在最佳条件下,该荧光方法在荧光淬灭效率与0.02 μmol/L至1.0 μmol/L的MG浓度之间呈现出良好的线性关系。该方法的检测限为0.67 μg/kg(3α/κ,n = 9),低于中国国家标准(GB/T 19857 - 2005)规定的限值(1 μg/kg)以及欧洲食品安全局(EFSA,2016)规定的限值(2 μg/kg)。通过加标标准品测试,回收率在87.1%至106.9%之间,相对标准偏差小于6.4%。数据经高效液相色谱法验证,结果证明所建立的荧光方法可用于鱼类中MG的快速检测,具有高准确性和灵敏度。