Suppr超能文献

使用六股和八股腘绳肌腱自体移植物进行前交叉韧带重建可产生足够的移植物尺寸和功能结果:一项系统评价。

Anterior cruciate ligament reconstruction with six and eight-strand hamstring tendon autografts produces adequate graft dimensions and functional outcomes: A systematic review.

作者信息

Sun Bryan, Lee Boss, Grad Justin, Cohen Dan, Abouali Jihad, Tapasvi Sachin, Maniar Adit, de Sa Darren

机构信息

Michael G. DeGroote School of Medicine, Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada.

Department of Surgery, Division of Orthopaedic Surgery, McMaster University, Hamilton, Ontario, Canada.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2025 Jun;33(6):2144-2155. doi: 10.1002/ksa.12556. Epub 2024 Dec 12.

Abstract

PURPOSE

This study aims to summarize the graft dimensions, failure rates, return-to-sport rates and patient-reported outcome measures (PROMs) following anterior cruciate ligament reconstruction (ACLR) with six or eight-strand hamstring tendon autografts (6SHG or 8SHG).

METHODS

Three databases were searched from inception to 12 February 2024. The authors adhered to PRISMA guidelines and the Cochrane Handbook for Systematic Reviews of Interventions. All clinical studies reporting patient demographics, objective clinical outcomes and PROMs following ACLR with 6SHG or 8SHG were included for data synthesis. PROMs included the International Knee Documentation Committee (IKDC), Lysholm and Tegner scores.

RESULTS

Thirteen studies comprising 1103 patients were included (mean age: 30.6 years). The transtibial technique was used in all studies, except one study using anatomic ACLR (n = 38), and one study using transtibial and all-inside ACLR (n = 41). Eight studies comprising 512 patients used 6SHG, four studies comprising 507 patients 8SHG and two studies comprising 97 patients used either. Mean graft diameters ranged from 8.0 to 9.2 mm (6SHG) and 9.1 to 9.9 mm (8SHG). Mean graft lengths for 49 6SHG patients ranged from 60.0 to 83.3 mm. The failure rate for 817 patients (6SHG or 8SHG) was 4.8% (0.0%-20.0%). The return-to-sport rate for 112 patients (6SHG or 8SHG) was 75.9% (69.7%-100.0%). Mean IKDC, Lysholm and Tegner scores for 6SHG or 8SHG were 88.4 (86.1-96.3), 91.7 (90.4-96.5) and 6.9 (6.5-7.3), respectively.

CONCLUSIONS

Both 6SHG and 8SHG produced graft diameters <8 mm. Data regarding PROMs suggested good patient satisfaction based on established criteria. Re-rupture and return-to-sport rates were 4.8% and 75.9%, respectively.

LEVEL OF EVIDENCE

Level IV.

摘要

目的

本研究旨在总结采用六股或八股腘绳肌腱自体移植物(6SHG或8SHG)进行前交叉韧带重建(ACLR)后的移植物尺寸、失败率、恢复运动率以及患者报告的结局指标(PROMs)。

方法

检索了三个数据库,检索时间从建库至2024年2月12日。作者遵循PRISMA指南和《Cochrane系统评价干预措施手册》。纳入所有报告ACLR采用6SHG或8SHG后的患者人口统计学、客观临床结局和PROMs的临床研究进行数据合成。PROMs包括国际膝关节文献委员会(IKDC)、Lysholm和Tegner评分。

结果

纳入13项研究,共1103例患者(平均年龄:30.6岁)。除一项采用解剖学ACLR的研究(n = 38)和一项采用经胫骨和全内ACLR的研究(n = 41)外,所有研究均采用经胫骨技术。八项研究共512例患者使用6SHG,四项研究共507例患者使用8SHG,两项研究共97例患者使用其中任意一种。平均移植物直径范围为8.0至9.2毫米(6SHG)和9.1至9.9毫米(8SHG)。49例6SHG患者的平均移植物长度范围为60.0至83.3毫米。817例患者(6SHG或8SHG)的失败率为4.8%(0.0%-20.0%)。112例患者(6SHG或8SHG)的恢复运动率为75.9%(69.7%-100.0%)。6SHG或8SHG的平均IKDC、Lysholm和Tegner评分分别为88.4(86.1-96.3)、91.7(90.4-96.5)和6.9(6.5-7.3)。

结论

6SHG和8SHG的移植物直径均<8毫米。基于既定标准的PROMs数据表明患者满意度良好。再破裂率和恢复运动率分别为4.8%和75.9%。

证据水平

四级。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验