Tisyakorn James, Saiphoklang Narongkorn, Sapankaew Tunlanut, Thapa Kristina, Anutariya Chutiporn, Sujarae Aekavute, Tepwimonpetkun Chatkarin
Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Faculty of Medicine, Thammasat University, Pathum Thani, Thailand.
Asian Institute of Technology School of Engineering and Technology, Pathum Thani, Thailand.
Sleep Breath. 2024 Dec 17;29(1):61. doi: 10.1007/s11325-024-03232-9.
Obstructive sleep apnea (OSA) is a highly prevalent sleep-related breathing disorder usually diagnosed through polysomnography (PSG). Moderate to severe OSA can significantly increase morbidity and mortality. Existing screening tools have limited accuracy. This study aimed to evaluate the Wellue O ring, a commercial pulse oximeter ring, for screening moderate to severe OSA.
A cross-sectional study included adults aged 18 and older suspected of having OSA who underwent PSG while wearing the Wellue O2 ring on their thumb. The oxygen desaturation index (ODI) from both the O2 ring and PSG was recorded. Sensitivity, specificity, and receiver operating characteristic (ROC) curves were calculated to determine the optimal ODI cutoff value for predicting moderate to severe OSA.
The study included 190 participants (53.2% male) with an average age of 43 years and an average apnea-hypopnea index (AHI) of 50.4 events per hour. Among the participants, 84.7% had moderate to severe OSA. The optimal cutoff value for 11% ODI was 1.25 events per hour lasting 20 s, with a sensitivity of 87.30% and a specificity of 78.70%. The area under the ROC curve for identifying moderate to severe OSA was 0.91.
The Wellue O2 ring demonstrated high accuracy in detecting moderate to severe OSA and could be a viable alternative for screening in clinical settings due to its accessibility and ease of use. However, larger studies are required to validate its clinical utility for diagnosing and managing moderate to severe OSA.
阻塞性睡眠呼吸暂停(OSA)是一种高度普遍的与睡眠相关的呼吸障碍,通常通过多导睡眠图(PSG)进行诊断。中度至重度OSA可显著增加发病率和死亡率。现有的筛查工具准确性有限。本研究旨在评估一款商业脉搏血氧仪指环Wellue O环用于筛查中度至重度OSA的效果。
一项横断面研究纳入了18岁及以上怀疑患有OSA的成年人,他们在拇指上佩戴Wellue O2环的同时接受PSG检查。记录来自O2环和PSG的氧饱和度下降指数(ODI)。计算敏感性、特异性和受试者工作特征(ROC)曲线,以确定预测中度至重度OSA的最佳ODI临界值。
该研究纳入了190名参与者(53.2%为男性),平均年龄43岁,平均呼吸暂停低通气指数(AHI)为每小时50.4次事件。在参与者中,84.7%患有中度至重度OSA。ODI为11%时的最佳临界值是每小时1.25次事件持续20秒,敏感性为87.30%,特异性为78.70%。识别中度至重度OSA的ROC曲线下面积为0.91。
Wellue O2环在检测中度至重度OSA方面显示出高准确性,由于其可及性和易用性,在临床环境中可能是一种可行的筛查替代方法。然而,需要更大规模的研究来验证其在诊断和管理中度至重度OSA方面的临床效用。