Suppr超能文献

氪-81m通气显像:在疑似肺栓塞中的临床应用

Kr-81m ventilation imaging: clinical utility in suspected pulmonary embolism.

作者信息

Rosen J M, Biello D R, Siegel B A, Seldin D W, Alderson P O

出版信息

Radiology. 1985 Mar;154(3):787-90. doi: 10.1148/radiology.154.3.3969485.

Abstract

The results of Kr-81m/Tc-99m ventilation-perfusion (VP) lung scintigraphy were correlated with the results of pulmonary angiography for 74 patients suspected of having pulmonary embolism (PE). Among patients having a diagnostic scan, the sensitivity and specificity of scintigraphy were 91% and 94%, respectively. Also, 157 consecutive cases of Kr-81m/Tc-99m VP lung scintigraphy were reviewed, and the frequency of an indeterminate scan was found to be 22%. A similar frequency was found for VP scintigraphy with xenon-133. Of eight patients who had indeterminate scans due to the presence of a single VP mismatch, four were demonstrated to have PE by angiography. Kr-81m is an excellent agent for VP scanning in cases of suspected PE, offering accuracy in diagnosis as well as favorable physical properties.

摘要

对74例疑似肺栓塞(PE)患者的Kr-81m/Tc-99m通气-灌注(VP)肺闪烁扫描结果与肺血管造影结果进行了相关性分析。在进行诊断性扫描的患者中,闪烁扫描的敏感性和特异性分别为91%和94%。此外,回顾了157例连续的Kr-81m/Tc-99m VP肺闪烁扫描病例,发现不确定扫描的频率为22%。用氙-133进行VP闪烁扫描也发现了类似的频率。在因单个VP不匹配而扫描结果不确定的8例患者中,有4例经血管造影证实患有PE。Kr-81m是疑似PE病例中VP扫描的优良剂,在诊断中具有准确性以及良好的物理特性。