Suppr超能文献

酰胺质子转移加权磁共振成像测量在胶质瘤患者中产生一致且可重复的结果:一项前瞻性重测研究。

Amide proton transfer weighted MRI measurements yield consistent and repeatable results in patients with gliomas: a prospective test-retest study.

作者信息

Pflüger Irada, Rastogi Aditya, Casagranda Stefano, Papageorgakis Christos, Behnisch Rouven, Liebig Patrick, Prager Marcel, Ippen Franziska Maria, Paech Daniel, Wick Wolfgang, Bendszus Martin, Brugnara Gianluca, Vollmuth Philipp

机构信息

Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany.

Division for Computational Neuroimaging, Heidelberg University Hospital, Heidelberg, Germany.

出版信息

Eur Radiol. 2025 Jun;35(6):3367-3379. doi: 10.1007/s00330-024-11197-2. Epub 2024 Dec 18.

Abstract

OBJECTIVES

Chemical exchange saturation transfer (CEST) imaging has emerged as a promising imaging biomarker, but its reliability for clinical practice remains uncertain. This study aimed to investigate the robustness of CEST parameters in healthy volunteers and patients with brain tumours.

METHODS

A total of n = 52 healthy volunteers and n = 52 patients with histologically confirmed glioma underwent two consecutive 3-T MRI scans separated by a 1-min break. The CEST measurements were reconstructed using two models: with and without fluid suppression and included the evaluation of both amide (amidePTw) and amine (aminePTw) offsets. Mean intensity values in healthy volunteers were compared from volumetric segmentations (VOI) of grey matter, white matter, and the whole brain. Mean intensity values in brain tumour patients were assessed from VOI of the contrast-enhancing, non-enhancing and whole tumour, as well as from the normal-appearing white matter. Test-retest reliability was assessed using ICC and Bland-Altman plots.

RESULTS

The amidePTw/aminePTw signal intensity distribution was significantly affected by fluid suppression (p < 0.001 for each VOI). Test-retest reliability in healthy volunteers showed fair to excellent agreement (ICC = 0.53-0.74), with the highest signal intensity values observed by amidePTw (ICC = 0.73-0.74). In patients, an excellent agreement of both amidePTw and aminePTw measurements was observed across different tumour regions (ICC = 0.76-0.89), with the highest ICC for contrast-enhancing tumour measurements. Bland-Altman analysis indicated negligible systematic bias and no proportional bias in measurement errors.

CONCLUSION

Measurements from amide/aminePTw imaging obtained from an adequately powered test-retest study yield consistent and reproducible results in glioma patients, as a prerequisite for robust imaging biomarker discovery in neuro-oncology.

KEY POINTS

Question The clinical reliability of chemical exchange saturation transfer imaging remains uncertain, necessitating further investigation to establish its robustness as a biomarker in neuro-oncology. Findings This study demonstrates that amide/amine proton transfer imaging provides repeatable, high-agreement measurements in glioma patients, particularly in contrast-enhancing tumour regions. Clinical relevance This test-retest study demonstrates that chemical exchange saturation transfer imaging using two models and assessing amide and amine offsets yield consistent and repeatable results in glioma patients, as a prerequisite for robust imaging biomarker discovery for neuro-oncology studies and clinical practice.

摘要

目的

化学交换饱和转移(CEST)成像已成为一种很有前景的成像生物标志物,但其在临床实践中的可靠性仍不确定。本研究旨在调查健康志愿者和脑肿瘤患者中CEST参数的稳健性。

方法

共有n = 52名健康志愿者和n = 52名经组织学确诊的胶质瘤患者接受了两次连续的3-T MRI扫描,中间间隔1分钟休息时间。CEST测量使用两种模型进行重建:有和没有液体抑制,并包括对酰胺(酰胺PTw)和胺(胺PTw)偏移的评估。从灰质、白质和全脑的体积分割(VOI)中比较健康志愿者的平均强度值。从增强、未增强和整个肿瘤的VOI以及正常外观的白质中评估脑肿瘤患者的平均强度值。使用组内相关系数(ICC)和Bland-Altman图评估重测可靠性。

结果

酰胺PTw/胺PTw信号强度分布受液体抑制的显著影响(每个VOI的p < 0.001)。健康志愿者的重测可靠性显示出良好到优秀的一致性(ICC = 0.53 - 0.74),酰胺PTw观察到最高的信号强度值(ICC = 0.73 - 0.74)。在患者中,在不同肿瘤区域观察到酰胺PTw和胺PTw测量的优秀一致性(ICC = 0.76 - 0.89),增强肿瘤测量的ICC最高。Bland-Altman分析表明测量误差中的系统偏差可忽略不计且无比例偏差。

结论

从一项有足够样本量的重测研究中获得的酰胺/胺PTw成像测量结果在胶质瘤患者中产生一致且可重复的结果,这是在神经肿瘤学中发现稳健成像生物标志物的前提条件。

关键点

问题 化学交换饱和转移成像的临床可靠性仍不确定,需要进一步研究以确定其作为神经肿瘤学中生物标志物的稳健性。发现 本研究表明酰胺/胺质子转移成像在胶质瘤患者中提供可重复的、高度一致的测量结果,特别是在增强肿瘤区域。临床意义 这项重测研究表明,使用两种模型并评估酰胺和胺偏移的化学交换饱和转移成像在胶质瘤患者中产生一致且可重复的结果,这是神经肿瘤学研究和临床实践中发现稳健成像生物标志物的前提条件。