Suppr超能文献

初始标本分流装置对中心静脉导管污染或定植检测影响的体外评估

In vitro assessment of effect of initial specimen diversion device on detection of central venous catheter contamination or colonization.

作者信息

Rupp Mark E, Fey Paul D, Lyden Elizabeth, Handke Luke

机构信息

Division of Infectious Diseases, University of Nebraska Medical Center, Omaha, NE, USA.

Department of Pathology, Microbiology, and Immunology, University of Nebraska Medical Center, Omaha, NE, USA.

出版信息

Infect Control Hosp Epidemiol. 2024 Dec 19;46(2):1-4. doi: 10.1017/ice.2024.220.

Abstract

The role of initial specimen diversion devices (ISDDs) in preventing contamination of central venous catheter (CVC) blood cultures is undefined. A model to simulate CVC colonization and contamination compared standard cultures with ISDD technique. ISDD detected 100% of colonized CVCs while decreasing false-positive cultures from 36% to 16%.

摘要

初始样本分流装置(ISDDs)在预防中心静脉导管(CVC)血培养污染方面的作用尚不明确。一个模拟CVC定植和污染的模型将标准培养与ISDD技术进行了比较。ISDD检测出了100%定植的CVC,同时将假阳性培养从36%降至16%。