Suppr超能文献

针对心肌肌钙蛋白I-心肌肌钙蛋白T-肌钙蛋白C复合物多种形式及片段形式的新型心肌肌钙蛋白检测方法的设计与分析评估

Design and Analytical Evaluation of Novel Cardiac Troponin Assays Targeting Multiple Forms of the Cardiac Troponin I-Cardiac Troponin T-Troponin C Complex and Fragmentation Forms.

作者信息

Li Ling, Liu Yuqing, Katrukha Ivan A, Zhang Litao, Shu Xin, Xu Ao, Yang Juan, Wu Yu, Jing Yisha, Wang Hui, Ni Tongxin, Schulz Karen, Bereznikova Anastasia V, Katrukha Alexey G, Apple Fred S, Zhang Yi, Zhang Zhenlu

机构信息

Clinical Laboratory, Wuhan Asia Heart Hospital, Wuhan, Hubei, China.

Immunoassay Reagent R&D Department, Shenzhen Mindray Bio-Medical Electronics Co., Ltd, Shenzhen, China.

出版信息

Clin Chem. 2025 Mar 3;71(3):387-395. doi: 10.1093/clinchem/hvae182.

Abstract

BACKGROUND

Current studies suggest that cardiac troponin (cTn) forms in the circulation may vary in different clinical scenarios. Our aim was to design a combination of cTn assays specific to the main cTn forms and to evaluate their analytical performance.

METHODS

We developed immunoassays specific for measuring (1) long-cTnT cTnI-cTnT-TnC (ITC) ternary complex, with cTnT in long form without cleavage at the C-terminal amino acids residue 189-223, designated "long-cTnT ITC complex assay;" (2) both the long-cTnT ITC complex plus short-cTnT ITC complex, designated "hs-total ITC complex assay;" (3) the central part of cTnT of both the long-cTnT ITC complex and free cTnT, designated "hs-cTnT assay." Sex-specific 99th percentile upper reference limits (URLs) were determined. High-sensitivity performance was assessed by examining the imprecision and detectable results above limit of detection (LoD) in the healthy population.

RESULTS

Both complex immunoassays exhibited excellent analytical sensitivity, precision, and specificity. The 99th percentile URLs were as follows: long-cTnT ITC complex: male 0.90 ng/L, female 0.87 ng/L; hs-total ITC complex: male 16.15 ng/L, female 10.08 ng/L; hs-cTnT: male 15.57 ng/L, female 14.28 ng/L. The total imprecision at or below the sex-specific 99th percentile URLs was <5% for all assays. The hs-total ITC complex and the hs-cTnT assays showed >50% of measurable concentrations above the LoD. However, <20% were measurable for the long-cTnT ITC complex assay.

CONCLUSIONS

The cTn assays detected concentrations of major cTn forms in the circulation with high sensitivity, precision, and specificity, supporting their use for monitoring cTn complex and fragmentation forms during myocardial injuries.

摘要

背景

目前的研究表明,循环中的心肌肌钙蛋白(cTn)形式在不同临床情况下可能有所不同。我们的目的是设计一种针对主要cTn形式的cTn检测组合,并评估其分析性能。

方法

我们开发了特异性免疫测定法,用于测量(1)长链cTnT的cTnI-cTnT-TnC(ITC)三元复合物,其中cTnT为长链形式,C末端氨基酸残基189-223未裂解,称为“长链cTnT ITC复合物测定法”;(2)长链cTnT ITC复合物加短链cTnT ITC复合物,称为“hs-总ITC复合物测定法”;(3)长链cTnT ITC复合物和游离cTnT的cTnT中心部分,称为“hs-cTnT测定法”。确定了性别特异性第99百分位数的上限参考值(URL)。通过检查健康人群中的不精密度和高于检测限(LoD)的可检测结果来评估高灵敏度性能。

结果

两种复合物免疫测定法均表现出优异的分析灵敏度、精密度和特异性。第99百分位数的URL如下:长链cTnT ITC复合物:男性0.90 ng/L,女性0.87 ng/L;hs-总ITC复合物:男性16.15 ng/L,女性10.08 ng/L;hs-cTnT:男性15.57 ng/L,女性14.28 ng/L。所有测定法在性别特异性第99百分位数URL及以下的总不精密度均<5%。hs-总ITC复合物和hs-cTnT测定法显示,>50%的可测量浓度高于LoD。然而,长链cTnT ITC复合物测定法的可测量浓度<20%。

结论

cTn检测法以高灵敏度、精密度和特异性检测循环中主要cTn形式的浓度,支持其在心肌损伤期间监测cTn复合物和片段化形式的应用。