连续作用加压装置用于第一跖趾关节融合术的疗效

The Outcome of the Use of Continuous Action Compression Device for the First Metatarsophalangeal Joint Fusion.

作者信息

Ismail Ahmed, Hannant Gary, Ashour Ahmed, Broadhurst Damian

机构信息

Orthopaedics, Bradford Royal Infirmary, Bradford, GBR.

Orthopaedics and Trauma, Bradford Royal Infirmity, Bradford, GBR.

出版信息

Cureus. 2024 Nov 21;16(11):e74168. doi: 10.7759/cureus.74168. eCollection 2024 Nov.

Abstract

INTRODUCTION

First metatarsophalangeal (MTP) joint fusion is a widely accepted surgical intervention for treating severe arthritis, deformities, and instability of the first MTP joint. This paper provides a review of a single surgeon's experience with continuous compression implants (CCI), which offer a notable advantage by providing uniform compression across a larger surface area of the fusion site compared to plate and screw constructs. This design potentially reduces soft tissue irritation and, consequently, the need for subsequent implant removal. It also saves on cost and has the potential to reduce the length of surgery.

METHODS

A retrospective review was conducted on 27 patients (n=36 feet) who underwent primary first metatarsophalangeal joint (MTPJ) fusion using continuous compression implants (CCI) between March 2020 and April 2024 at Bradford Royal Infirmary. Patient data were collected from the surgeon's logbook and medical records. The outcomes analyzed included the fusion rate and complications. Statistical analysis was performed using SPSS version 22.0, with p<0.05 considered significant.

RESULTS

The mean age of the cohort was 60.24 years (range 41-90), with 88.88% female. The ratio of left to right was 70%. The mean follow-up duration was 27 months (range 6-48 months). Complete fusion of the first MTPJ was achieved in 34 out of 36 feet (94.4%). Nonunion occurred in one patient, while delayed union was observed in another. Clinically, 35 out of 36 patients (97.3%) reported satisfaction with the procedure, with one patient requiring metalwork removal and revision due to loosening.

CONCLUSION

Early results show that the rate of fusion achieved by using the CCI for the first MTPJ arthrodesis in our series was comparable to that of other devices quoted in the literature.

摘要

引言

第一跖趾关节融合术是治疗第一跖趾关节严重关节炎、畸形和不稳定的一种广泛接受的外科手术。本文回顾了一位外科医生使用持续加压植入物(CCI)的经验,与钢板和螺钉结构相比,持续加压植入物通过在融合部位的更大表面积上提供均匀加压具有显著优势。这种设计可能减少软组织刺激,从而减少后续取出植入物的需求。它还节省成本,并有可能缩短手术时间。

方法

对2020年3月至2024年4月在布拉德福德皇家医院使用持续加压植入物(CCI)进行初次第一跖趾关节(MTPJ)融合术的27例患者(n = 36足)进行回顾性研究。患者数据从外科医生的日志和病历中收集。分析的结果包括融合率和并发症。使用SPSS 22.0版进行统计分析,p < 0.05被认为具有统计学意义。

结果

该队列的平均年龄为60.24岁(范围41 - 90岁),女性占88.88%。左右比例为70%。平均随访时间为27个月(范围6 - 48个月)。36足中的34足(94.4%)实现了第一跖趾关节的完全融合。1例患者发生骨不连,另1例观察到延迟愈合。临床上,36例患者中的35例(97.3%)对手术表示满意,1例患者因松动需要取出金属植入物并进行翻修。

结论

早期结果表明,在我们的系列研究中,使用持续加压植入物进行第一跖趾关节融合术的融合率与文献中引用的其他装置相当。