Suppr超能文献

电感耦合等离子体质谱法测定关键血清矿物质的性能:与标准定量方法的比较研究

Inductively Coupled Plasma Mass Spectrometry Performance for the Measurement of Key Serum Minerals: A Comparative Study With Standard Quantification Methods.

作者信息

Kojo Kosuke, Oguri Tomoko, Tanaka Takazo, Ikeda Atsushi, Shimizu Takuya, Fujimoto Shunsuke, Nakazono Ayumi, Nagumo Yoshiyuki, Kandori Shuya, Negoro Hiromitsu, Nishiyama Hiroyuki

机构信息

Department of Urology, Institute of Medicine University of Tsukuba, Tsukuba, Japan.

Center for Human Reproduction, International University of Health and Welfare Hospital, Nasushiobara, Japan.

出版信息

J Clin Lab Anal. 2025 Jan;39(2):e25140. doi: 10.1002/jcla.25140. Epub 2024 Dec 23.

Abstract

BACKGROUND

Inductively coupled plasma mass spectrometry (ICP-MS) is widely used for the accurate measurement of minerals. However, its application to serum essential mineral measurement has not been fully evaluated. The present study aimed to assess the performance of ICP-MS for serum minerals by comparing its measurements to those obtained using standard quantification methods.

METHODS

Cross-sectional data were collected from 282 participants from a single facility in Japan. Serum concentrations of eight key minerals, namely sodium, potassium, calcium, phosphorus, magnesium, iron, zinc, and copper, measured via ICP-MS and standard methods were compared using Passing-Bablok regression and Bland-Altman plots.

RESULTS

All minerals, except phosphorus, exhibited good agreement with standard methods, with more stable regression coefficients observed for minerals with greater interindividual variability. After systematically filtering outliers, the mean relative errors were approximately -3% for sodium, potassium, calcium, and magnesium; +5% for iron; 0% for zinc; and -19% for copper. The outliers for iron were primarily due to mild hemolysis, whereas those for zinc were largely attributed to nonhemolysis factors. For phosphorus, the serum total phosphorus concentration measured using ICP-MS was approximately 3.5 times higher than the serum inorganic phosphorus concentration measured using standard methods, with a weak correlation observed between the two methods.

CONCLUSION

This study provides a practical foundation for future research. Understanding ICP-MS characteristics will facilitate the development of new approaches in clinical diagnostics.

摘要

背景

电感耦合等离子体质谱法(ICP-MS)广泛用于矿物质的准确测量。然而,其在血清必需矿物质测量中的应用尚未得到充分评估。本研究旨在通过将ICP-MS的测量结果与使用标准定量方法获得的结果进行比较,评估ICP-MS在血清矿物质测量方面的性能。

方法

从日本一个机构的282名参与者中收集横断面数据。使用Passing-Bablok回归和Bland-Altman图比较通过ICP-MS和标准方法测量的八种关键矿物质(即钠、钾、钙、磷、镁、铁、锌和铜)的血清浓度。

结果

除磷外,所有矿物质与标准方法均表现出良好的一致性,个体间变异性较大的矿物质观察到更稳定的回归系数。在系统过滤异常值后,钠、钾、钙和镁的平均相对误差约为-3%;铁为+5%;锌为0%;铜为-19%。铁的异常值主要是由于轻度溶血,而锌的异常值很大程度上归因于非溶血因素。对于磷,使用ICP-MS测量的血清总磷浓度约为使用标准方法测量的血清无机磷浓度的3.5倍,两种方法之间观察到弱相关性。

结论

本研究为未来研究提供了实践基础。了解ICP-MS的特性将有助于临床诊断新方法的开发。