Suppr超能文献

侧腹肌对负荷姿势反应的M型超声评估:一项探索性研究。

M-mode ultrasound evaluation of lateral abdominal muscle postural response to load: an exploratory study.

作者信息

Biały Maciej, Adamczyk Wacław Marceli, Stranc Tomasz, Szlachta Grzegorz, Gnat Rafał

机构信息

Institute of Physiotherapy and Health Sciences, The Jerzy Kukuczka Academy of Physical Education, Katowice, Poland.

Functional Diagnostics Laboratory, Sport-Klinika, Scanmed Sport, Żory, Poland.

出版信息

J Ultrason. 2024 Dec 23;24(99):1-7. doi: 10.15557/jou.2024.0037. eCollection 2024 Dec.

Abstract

AIM

There is a need to evaluate the tissue deformation index of lateral abdominal muscles using M-mode ultrasound in a cohort of healthy subjects to establish a convenient reference point for clinical reasoning in patients. The aim of the study was to assess differences in the tissue deformation index between individual lateral abdominal muscles regardless of body side, compare these differences in the tissue deformation index on the right and left sides of the body, and evaluate side-to-side differences in the tissue deformation index within individual lateral abdominal muscles.

MATERIAL AND METHODS

In a group of 126 healthy volunteers (59 females), the postural response of lateral abdominal muscles to external perturbation in the form of rapid arm abduction with load was recorded on both sides of the body, and the tissue deformation index was calculated.

RESULTS

The mean values of the tissue deformation index form an increasing gradient from deep to superficial lateral abdominal muscles: 0.06%/ms for the transversus abdominis, 0.084%/ms for the internal oblique and 0.151%/ms for the external oblique ( <0.001). Side-to-side intra-muscle differences were significant only for the transverse abdominis (right: 0.047%/ms; left: 0.070%; <0.01).

CONCLUSIONS

The tissue deformation index values differ significantly among individual lateral abdominal muscles and form a characteristic gradient: transversus abdominis < internal oblique < external oblique. The transversus abdominis muscle shows significant asymmetry in the tissue deformation index between the left and right sides of the body.

摘要

目的

有必要在一组健康受试者中使用M型超声评估侧腹部肌肉的组织变形指数,以便为患者的临床推理建立一个方便的参考点。本研究的目的是评估各个侧腹部肌肉之间的组织变形指数差异(不考虑身体侧别),比较身体左右两侧组织变形指数的这些差异,并评估各个侧腹部肌肉内组织变形指数的左右差异。

材料与方法

在一组126名健康志愿者(59名女性)中,记录了身体两侧侧腹部肌肉对以负重快速手臂外展形式的外部扰动的姿势反应,并计算了组织变形指数。

结果

组织变形指数的平均值从深层到浅层侧腹部肌肉形成一个递增梯度:腹横肌为0.06%/ms,腹内斜肌为0.084%/ms,腹外斜肌为0.151%/ms(<0.001)。仅腹横肌的肌肉内左右差异具有显著性(右侧:0.047%/ms;左侧:0.070%;<0.01)。

结论

各个侧腹部肌肉之间的组织变形指数值存在显著差异,并形成一个特征梯度:腹横肌<腹内斜肌<腹外斜肌。腹横肌在身体左右两侧的组织变形指数显示出显著的不对称性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a154/11665055/72599285a2bc/j_jou.2024.0037_fig_001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验