对比增强超声造影(CEM)和磁共振成像(MRI)中背景实质强化:二者总是高度一致吗?

Background parenchymal enhancement in CEM and MRI: Is there always a high agreement?

作者信息

Ferrara Francesca, Santonocito Ambra, Vogel William, Trombadori Charlotte, Zarcaro Calogero, Weber Michael, Kapetas Panagiotis, Helbich Thomas H, Baltzer Pascal A T, Clauser Paola

机构信息

Department of Radiology, Radiation Oncology and Hematology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy.

Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, Vienna 1180, Austria.

出版信息

Eur J Radiol. 2025 Feb;183:111903. doi: 10.1016/j.ejrad.2024.111903. Epub 2024 Dec 25.

Abstract

INTRODUCTION

Background parenchymal enhancement (BPE) refers to the physiological enhancement of breast fibroglandular tissue. This study aimed to determine the agreement of BPE evaluation between contrast enhanced mammography (CEM) and magnetic resonance imaging (MRI) and investigate potential confounders.

MATERIALS AND METHODS

This retrospective, IRB-approved study included women recalled from screening or with inconclusive findings on mammography and/or ultrasound, who underwent both CEM and MRI between 2018 and 2022. Imaging protocols followed international recommendations. Two breast radiology fellows assessed density and BPE on CEM and MRI using BI-RADS, evaluating the early post-contrast acquisition (EP). In addition, BPE on MRI was assessed in the late post-contrast acquisition (LP). Data on menopausal status, breast thickness, and compression force were retrieved. Univariate and multivariate analyses were used.

RESULTS

343 patients were consecutively enrolled. Post-menopausal patients showed lower BPE levels (p < 0.001). Agreement on BPE levels between CEM and MRI in the EP was fair (R1 κ = 0.342, R2 κ = 0.383). In the LP agreement was moderate for R1 (κ = 0.432) and fair for R2 (κ 0.368). There was a significant correlation between BPE and density in CEM (R1 ρ 0.399, R2 ρ 0.441; p < 0.001). A negative correlation was found on CEM between BPE and compression force (ρ -0.100, p = 0.001). Inter-reader agreement was high with both modalities (CEM κ = 0.678, MRI-EP κ = 0.690, MRI-EP κ = 0.692).

CONCLUSIONS

The agreement of BPE assessment between MRI and CEM was fair to moderate and reproducibility among readers was high. Compression force and mammographic breast density seem to influence BPE levels in CEM.

摘要

引言

背景实质强化(BPE)是指乳腺纤维腺组织的生理性强化。本研究旨在确定对比增强乳腺X线摄影(CEM)和磁共振成像(MRI)在BPE评估方面的一致性,并调查潜在的混杂因素。

材料与方法

这项经机构审查委员会批准的回顾性研究纳入了因筛查被召回或乳腺X线摄影和/或超声检查结果不确定的女性,她们在2018年至2022年期间接受了CEM和MRI检查。成像方案遵循国际建议。两名乳腺放射科住院医师使用乳腺影像报告和数据系统(BI-RADS)评估CEM和MRI上的密度和BPE,评估对比剂注射后的早期图像(EP)。此外,在对比剂注射后的晚期图像(LP)上评估MRI上的BPE。收集绝经状态、乳腺厚度和压迫力的数据。采用单因素和多因素分析。

结果

连续纳入343例患者。绝经后患者的BPE水平较低(p < 0.001)。在EP中,CEM和MRI在BPE水平上的一致性为中等(R1 κ = 0.342,R2 κ = 0.383)。在LP中,R1的一致性为中等(κ = 0.432),R2的一致性为中等(κ = 0.368)。CEM中BPE与密度之间存在显著相关性(R1 ρ = 0.399,R2 ρ = 0.441;p < 0.001)。CEM中发现BPE与压迫力之间呈负相关(ρ = -0.100,p = 0.001)。两种检查方法的阅片者间一致性都很高(CEM κ = 0.678,MRI-EP κ = 0.690,MRI-LP κ = 0.692)。

结论

MRI和CEM在BPE评估方面的一致性为中等,阅片者间的可重复性很高。压迫力和乳腺X线摄影的乳腺密度似乎会影响CEM中的BPE水平。