Nasution Mutia A, Lubis Hilda F, Sipayung Ingrid V, Sitepu Inri N
Department of Orthodontics, Faculty of Dentistry, Universitas Sumatera Utara, Medan, Indonesia.
J Orthod Sci. 2024 Nov 25;13:53. doi: 10.4103/jos.jos_188_23. eCollection 2024.
This study aimed at determining the effect of pH changes on nickel titanium wire seen based on the corrosion rate and surface roughness of the wire after immersion in pandan leaves extract.
The sample used nickel titanium wire of 0.016 inches diameter and 5 cm length and consists of five treatment groups: control group, 0.2% chlorhexidine, and 1000 ppm, 2000 ppm, and 4000 ppm pandan leaves extract. The solutions were put into an incubator for 7, 14, and 21 days at 37 °C and removed according to the sample immersion time. The corrosion rate was determined using the weight-loss method, and microstructure roughness was analyzed using a .
test showed that there was a significant difference in corrosion rate of orthodontic wires of after control submersion, 0.2% chlorhexidine, and pandan leaves extract on 7, 14, and 21 days ( ≤ 0.05), and pandan leaves extract submersion shows that the surface structure is not as bad as artificial saliva and 0.2% chlorhexidine.
Pandan leaves extract could inhibit the corrosion rate of nickel titanium orthodontic wire, which might be due to tannin content as an active antioxidant.
本研究旨在通过观察镍钛丝在露兜树叶提取物中浸泡后的腐蚀速率和表面粗糙度,确定pH值变化对其的影响。
样本采用直径0.016英寸、长度5厘米的镍钛丝,分为五个处理组:对照组、0.2%氯己定组以及1000 ppm、2000 ppm和4000 ppm的露兜树叶提取物组。将溶液置于37℃的培养箱中7天、14天和21天,根据样本浸泡时间取出。采用失重法测定腐蚀速率,使用[此处原文缺失具体仪器名称]分析微观结构粗糙度。
测试表明,对照组、0.2%氯己定组以及露兜树叶提取物组在7天、14天和21天后正畸丝的腐蚀速率存在显著差异(P≤0.05),露兜树叶提取物浸泡后的表面结构不如人工唾液和0.2%氯己定组严重。
露兜树叶提取物可抑制镍钛正畸丝的腐蚀速率,这可能归因于其作为活性抗氧化剂的单宁含量。