Suppr超能文献

解剖型全肩关节置换翻修的组件混合匹配:一例病例报告

Component Mix-Match for Anatomic Total Shoulder Arthroplasty Revision: A Case Report.

作者信息

Tsolis Ilias, Atia Fady, Wijeratna Malin

机构信息

Hand and Upper Limb Unit, Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, GBR.

Trauma and Orthopaedics, Nottingham University Hospital, Nottingham, GBR.

出版信息

Cureus. 2024 Dec 4;16(12):e75092. doi: 10.7759/cureus.75092. eCollection 2024 Dec.

Abstract

Although mixing and matching components is a common, safe, and well-documented practice in hip revision surgery, our extensive search indicates that it has not been previously reported for shoulder arthroplasty. This case report presents the use of mixed implants in shoulder revision surgery to reduce morbidity and address flaws in the initial implant design. We describe a case of a patient with multiple epiphyseal dysplasia who was treated for osteoarthritis in his left shoulder with an anatomic shoulder replacement in 2014. In 2018, the patient presented with deteriorating function, increasing pain, and radiological signs of glenoid component wear and loosening. A decision was made to proceed with revision shoulder arthroplasty. Given the patient's young age and intact rotator cuff function, the revision was planned as an anatomic construct. The challenge was a well-fixed, fully hydroxyapatite-coated stem and a glenoid metal-backed component with a failing polyethylene locking mechanism. After extensive discussion with the patient, a combined decision was made to retain the well-fixed humeral stem and revise the glenoid side using impaction grafting with allograft, followed by cementing an all-polyethylene glenoid from a different company. The revision surgery was performed uneventfully, resulting in pain relief and improved function beyond the levels achieved in the initial operation. Notably, the original head and the revision glenoid had a curvature radius mismatch, in contrast to the original design's absolute congruence. Recent studies suggest that such a mismatch, within limits, can recreate normal shoulder kinematics and reduce glenoid loosening.

摘要

尽管在髋关节翻修手术中混合搭配组件是一种常见、安全且有充分文献记载的做法,但我们广泛的检索表明,此前在肩关节置换术中尚未有过相关报道。本病例报告介绍了在肩关节翻修手术中使用混合植入物以降低发病率并解决初始植入物设计缺陷的情况。我们描述了一例患有多发性骨骺发育不良的患者,他于2014年接受了左肩关节解剖型置换术以治疗骨关节炎。2018年,该患者出现功能恶化、疼痛加剧以及肩胛盂组件磨损和松动的影像学表现。决定进行肩关节翻修手术。鉴于患者年轻且肩袖功能完好,翻修手术计划采用解剖型结构。面临的挑战是一个固定良好、完全羟基磷灰石涂层的柄以及一个聚乙烯锁定机制失效的金属背衬肩胛盂组件。在与患者进行广泛讨论后,共同决定保留固定良好的肱骨干,并使用同种异体骨打压植骨对肩胛盂侧进行翻修,随后用来自不同公司生产的全聚乙烯肩胛盂进行骨水泥固定。翻修手术顺利完成,疼痛缓解,功能改善程度超过了初次手术。值得注意的是,与原始设计的绝对匹配不同,原来的股骨头与翻修后的肩胛盂曲率半径不匹配。最近的研究表明,在一定限度内,这种不匹配可以重建正常的肩关节运动学并减少肩胛盂松动。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/77a9/11697996/3065f25c08d4/cureus-0016-00000075092-i01.jpg

相似文献

本文引用的文献

5
The effect of radial mismatch on radiographic glenoid loosening.径向不匹配对影像学上肩胛盂松动的影响。
JSES Open Access. 2019 Nov 18;3(4):287-291. doi: 10.1016/j.jses.2019.09.007. eCollection 2019 Dec.
10
Multiple epiphyseal dysplasia.多发性骨骺发育不良
J Am Acad Orthop Surg. 2015 Mar;23(3):164-72. doi: 10.5435/JAAOS-D-13-00173. Epub 2015 Feb 9.