BACKGROUND

Current endogenous indicators utilised in avian medicine are not sensitive enough to detect renal disease in its early stages. Alternative markers ought to be examined as a result. The aim is to investigate the accuracy of limited-sampling models for glomerular filtration rate (GFR) in adult seagulls using plasma clearance of iohexol (IOX).

RESULTS

We compared the GFR estimated from the plasma concentration of IOX at 3 sampling times, known as limited sampling models, with that estimated from the plasma concentration of IOX at 6 sampling times (reference model). The reference model's mean ± SD for GFR was 6.88 ± 2.46 mL/min/kg and did not considerably differ from the GFR predicted by the limited-sampling models. Model 4, in which GFR was estimated using plasma IOX concentrations at 5, 15, and 90 min after IOX administration, had the smallest GFR bias compared to the reference model.

CONCLUSIONS

The findings revealed that IOX plasma clearance was a reliable, accurate, and clinically applicable approach to calculating seagull GFR. This strategy might help with the validation and subsequent development of clinical renal biomarkers.

摘要

背景

当前禽医学中使用的内源性指标在检测肾脏疾病早期阶段时不够敏感。因此,应研究替代标志物。目的是使用碘海醇(IOX)的血浆清除率来研究成年海鸥肾小球滤过率(GFR)有限采样模型的准确性。

结果

我们将在3个采样时间点根据IOX血浆浓度估算的GFR(即有限采样模型)与在6个采样时间点根据IOX血浆浓度估算的GFR(参考模型)进行了比较。参考模型的GFR均值±标准差为6.88±2.46 mL/(min·kg),与有限采样模型预测的GFR没有显著差异。模型4在IOX给药后5、15和90分钟使用血浆IOX浓度估算GFR,与参考模型相比,其GFR偏差最小。

结论

研究结果表明,IOX血浆清除率是一种可靠、准确且临床适用的计算海鸥GFR的方法。该策略可能有助于临床肾脏生物标志物的验证及后续开发。