Suppr超能文献

一种通过使用新的精确高效液相色谱法测量碘海醇血浆浓度来测定猫肾小球滤过率的有限采样、简单且有用的方法。

A Limited Sampling, Simple, and Useful Method for Determination of Glomerular Filtration Rate in Cats by Using a New Accurate HPLC Method to Measure Iohexol Plasmatic Concentrations.

作者信息

Valentina Meucci, Grazia Guidi, Pierre Melanie, Gloria Breghi, Ilaria Lippi

机构信息

Department of Veterinary Clinics, University of Pisa, San Piero a Grado, Via Livornese Lato Monte, 56122 Pisa, Italy.

出版信息

J Vet Med. 2013;2013:569121. doi: 10.1155/2013/569121. Epub 2013 Nov 12.

Abstract

Glomerular filtration rate (GFR) is still a highly underutilized tool in cats because available methods are not easy to be performed in clinical practice. Iohexol (IOX) has been shown to be a useful and reliable marker of GFR both in animals and in humans. The aim of the present study was to develop a rapid and reliable method for measuring IOX in feline plasma and to evaluate the accuracy of limited sampling models to establish a low-cost and clinically suitable GFR test. IOX concentrations were determined by using a new HPLC-UV method. GFR was assessed as plasma clearance of IOX, which was calculated by dividing dose administered by area under the curve of plasmatic concentration versus time (AUC), and indexed to body weight (BW). Correlation and agreement analysis between the GFR values obtained by a seven-point clearance method and the GFR values determined by the application of simplified sample combinations indicated that the 3-blood sample clearance model (5, 30, and 60 min) was the best simplified method because it provided an accurate GFR value in only one hour. The reported method is a simple and accurate way of GFR determination, which may be easily used in a clinical setting.

摘要

肾小球滤过率(GFR)在猫科动物中仍是一种未得到充分利用的工具,因为现有的检测方法在临床实践中不易操作。碘海醇(IOX)已被证明在动物和人类中都是一种有用且可靠的GFR标志物。本研究的目的是开发一种快速、可靠的方法来测定猫血浆中的碘海醇,并评估有限采样模型的准确性,以建立一种低成本且适合临床的GFR检测方法。采用一种新的高效液相色谱 - 紫外法测定碘海醇浓度。GFR通过碘海醇的血浆清除率来评估,即给药剂量除以血浆浓度 - 时间曲线下面积(AUC),并根据体重(BW)进行校正。通过七点清除法获得的GFR值与应用简化样本组合确定的GFR值之间的相关性和一致性分析表明,三点血样清除模型(5、30和60分钟)是最佳的简化方法,因为它仅需一小时就能提供准确的GFR值。所报道的方法是一种简单、准确的GFR测定方法,可轻松应用于临床环境。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6fc4/4590869/00c2862c4a62/JVM2013-569121.001.jpg