Abstract

Two patients underwent resection and replacement of the ascending aorta using a low-porosity Teflon graft anastomosed with silk suture. In both patients false aneurysms developed that required operation 13 and 23 years postoperatively. The clinical courses of these patients, along with data from the literature, suggest that the combination of a low-porosity Teflon graft and a silk suture anastomosis presents a major potential hazard for the development of anastomotic false aneurysm.

摘要

两名患者接受了升主动脉切除并使用低孔隙率聚四氟乙烯移植物与丝线缝合进行置换。两名患者均发生了假性动脉瘤,分别在术后13年和23年需要再次手术。这些患者的临床病程以及文献数据表明,低孔隙率聚四氟乙烯移植物与丝线缝合吻合术的组合存在发生吻合口假性动脉瘤的重大潜在风险。