Suppr超能文献

对胸腔引流管和经皮引流管进行标准化比较,以评估“法式”尺寸单位的适用性。

A standardised comparison of chest and percutaneous drainage catheters to evaluate the applicability of the 'French' sizing units.

作者信息

Daga Karan, Milward Graham D, Pintos Dos Santos Daniel, Edwards Derek W, Laasch Hans-Ulrich

机构信息

Guy's and St. Thomas' Hospital, London, UK.

Minnova Medical Foundation CIC, Wilmslow, UK.

出版信息

Sci Rep. 2025 Jan 10;15(1):1601. doi: 10.1038/s41598-024-71935-w.

Abstract

A variety of medical specialities undertake percutaneous drainage but understanding of device performance outside radiology is often limited. Furthermore, the current catheter sizing using the "French" measurement of outer diameter is unhelpful; it does not reflect the internal diameter and gives no information on flow rate. To illustrate this and to improve catheter selection, notably for chest drainage, we assessed the variation of drain performance under standardised conditions. Internal diameter and flow rates of 6Fr.-12Fr. drainage catheters from 8 manufacturers were tested to ISO 10555-1 standard: Internal diameters were measured with Meyer calibrated pin-gauges. Flow rates were calculated over a period of 30s after achieving steady state. Evaluation demonstrated a wide range of internal diameters for the 6Fr., 8Fr., 10Fr. and 12Fr. catheters. Mean measurements were 1.49 mm (SD:0.07), 1.90 mm (SD:0.10), 2.43 mm (SD:0.11) and 2.64 mm (SD:0.03) respectively. Mean flow rates were 128 mL/min (SD:37.6), 207 mL/min (SD: 55.1), 291 mL/min (SD:36.7) and 303 mL/min (SD:20.2) respectively. There was such variance that there was overlap between catheters of different size: thin-walled 10Fr. drains performed better than 12Fr. "Seldinger" chest drains. Better understanding of drain characteristics and better declaration of performance data by manufacturers are required to allow optimum drain choice for individual patients and optimum outcomes.

摘要

多种医学专科都进行经皮引流,但对放射科以外设备性能的了解往往有限。此外,目前使用外径“法式”测量的导管尺寸选择并无帮助;它不能反映内径,也没有给出流速信息。为了说明这一点并改进导管选择,特别是用于胸腔引流的导管,我们在标准化条件下评估了引流性能的变化。对来自8家制造商的6Fr.-12Fr.引流导管的内径和流速进行了符合ISO 10555-1标准的测试:内径用迈耶校准针规测量。在达到稳态后30秒内计算流速。评估表明,6Fr.、8Fr.、10Fr.和12Fr.导管的内径范围很广。平均测量值分别为1.49毫米(标准差:0.07)、1.90毫米(标准差:0.10)、2.43毫米(标准差:0.11)和2.64毫米(标准差:0.03)。平均流速分别为128毫升/分钟(标准差:37.6)、207毫升/分钟(标准差:55.1)、291毫升/分钟(标准差:36.7)和303毫升/分钟(标准差:20.2)。存在如此大的差异,以至于不同尺寸的导管之间存在重叠:薄壁10Fr.引流管的性能优于12Fr. “塞尔丁格”胸腔引流管。需要更好地了解引流管特性以及制造商更好地公布性能数据,以便为个体患者选择最佳引流管并实现最佳治疗效果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/829b/11724086/3a28dd7c3997/41598_2024_71935_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验