Suppr超能文献

用于预测胶囊内镜滞留的通畅性胶囊及横断面成像:一项系统评价与Meta分析

Patency Capsule and Cross-Sectional Imaging for Predicting Capsule Endoscopy Retention: A Systematic Review and Meta-Analysis.

作者信息

Kim Yeong Eun, Kim Pyeong Hwa, Yoon Hee Mang, Lee Jin Seong, Jung Ah Young, Cho Young Ah, Oh Seak Hee, Kim Kyung Mo

机构信息

Department of Pediatrics, Yonsei University College of Medicine, Severance Hospital, 50-1, Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, Republic of Korea.

Department of Pediatrics, University of Ulsan College of Medicine, Asan Medical Center Children's Hospital, 88, Olympic-ro 43-Gil, Songpa-Gu, Seoul, 05505, Republic of Korea.

出版信息

Dig Dis Sci. 2025 Feb;70(2):761-773. doi: 10.1007/s10620-024-08835-6. Epub 2025 Jan 13.

Abstract

AIMS

Small bowel capsule endoscopy, which has been widely used to evaluate small bowel disease, has a risk of capsule retention (CR). The present systematic review and meta-analysis evaluated the accuracy of patency capsule (PC) and cross-sectional imaging (CSI) for predicting CR.

METHODS

Databases, including MEDLINE/PubMed, EMBASE, Web of Science and the Cochrane library, were searched for articles through August 15, 2023, that investigated the diagnostic accuracy of PC or CSI for predicting CR. Pooled sensitivity and specificity were calculated using a bivariate random-effects model. The false-negative rates of PC and CSI were separately analyzed and compared using a single-proportion meta-analysis based on random-effects modeling.

RESULTS

Twenty-three articles (covering 3273 patients) including 17 assessing PC (involving 3051 patients), 4 assessing CSI (involving 140 patients), and 2 assessing both PC and CSI (involving 82 patients) were identified. CSI had a pooled sensitivity and specificity for predicting CR of 54% (95% confidence interval [CI], 21-84%) and 88% (95% CI, 67-97%), respectively, whereas PC had a pooled sensitivity and specificity for predicting CR of 75% (95% CI, 43-92%) and 94% (95% CI, 90-96%), respectively. PC showed a significantly higher specificity (P = 0.05) and lower pooled false-negative rate than CSI (2.7% [95% CI, 1.3-5.4%] vs. 12.8% [95% CI, 6.1-25.0%]; P = 0.001).

CONCLUSIONS

PC showed demonstrated comparable sensitivity, significantly higher specificity, and significantly lower false-negative rate than CSI. PC may be a more reliable modality for predicting CR than CSI.

摘要

目的

小肠胶囊内镜已广泛用于评估小肠疾病,但存在胶囊滞留(CR)风险。本系统评价和荟萃分析评估了通畅性胶囊(PC)和横断面成像(CSI)预测CR的准确性。

方法

检索MEDLINE/PubMed、EMBASE、Web of Science和Cochrane图书馆等数据库,查找截至2023年8月15日研究PC或CSI预测CR诊断准确性的文章。使用双变量随机效应模型计算合并敏感性和特异性。基于随机效应模型,采用单比例荟萃分析分别分析和比较PC和CSI的假阴性率。

结果

共纳入23篇文章(涵盖3273例患者),其中17篇评估PC(涉及3051例患者),4篇评估CSI(涉及140例患者),2篇同时评估PC和CSI(涉及82例患者)。CSI预测CR的合并敏感性和特异性分别为54%(95%置信区间[CI],21 - 84%)和88%(95%CI,67 - 97%),而PC预测CR的合并敏感性和特异性分别为75%(95%CI,43 - 92%)和94%(95%CI,90 - 96%)。与CSI相比,PC显示出显著更高的特异性(P = 0.05)和更低的合并假阴性率(2.7%[95%CI,1.3 - 5.4%]对12.8%[95%CI,6.1 - 25.0%];P = 0.001)。

结论

与CSI相比,PC显示出相当的敏感性、显著更高的特异性和显著更低的假阴性率。在预测CR方面,PC可能比CSI更可靠。