Suppr超能文献

线性位置传感器在卧推过程中测量杠铃速度、持续时间和位移的有效性与可靠性

Validity and Reliability of a Linear Position Transducer to Measure Barbell Velocity, Duration, and Displacement During the Bench Press.

作者信息

Pinzone Anthony G, Gant Ryan W, Rivera Jennifer, Pelka Edward Z, Tagesen Emily C, Lebron Modesto A, Jajtner Adam R

机构信息

Exercise Science and Exercise Physiology Program, Kent State University, Kent, OH, USA.

School of Kinesiology and Physical Therapy, University of Central Florida, Orlando, FL, USA.

出版信息

Int J Exerc Sci. 2024 Dec 1;17(7):1294-1305. doi: 10.70252/MFJK8861. eCollection 2024.

Abstract

This investigation evaluated validity and reliability of the HUMAC360 linear position transducer (LPT) compared to the Tendo Sport Weightlifting Analyzer (TENDO) for measuring mean velocity (MV), peak velocity (PV), and displacement (D) during the bench press. Seventeen recreationally active individuals completed three visits. During visit one, participants were assessed for their one repetition maximum (1RM) bench press. During subsequent visits, participants completed two sets of three repetitions of bench press at 30, 50, 60, and 70% 1RM. The HUMAC and TENDO measured MV, PV, and D simultaneously, while the HUMAC also measured repetition duration (T). Validity of the HUMAC and inter-set and inter-day reliability for MV, PV, D, and T were assessed using Intraclass Correlation Coefficients (ICCs). The HUMAC demonstrated limited validity when compared to the TENDO as ICCs ranged from poor to good across all measurements. Significant differences were observed between devices for MV, PV, and D at all intensities ( < 0.001). Inter-set reliability was excellent for all intensities and measurements, but inter-day reliability was impaired for MV, PV, and D at higher intensities. Validity of the HUMAC for measuring MV, PV, and D is limited when compared to TENDO. As the HUMAC reliably assesses MV, PV, D, and T, both inter-set and interday (up to 60% 1RM), it may serve as an autoregulatory tool for velocity-based training.

摘要

本研究评估了HUMAC360线性位置传感器(LPT)与Tendo运动举重分析仪(TENDO)相比,在卧推过程中测量平均速度(MV)、峰值速度(PV)和位移(D)的有效性和可靠性。17名有运动习惯的个体完成了三次测试。在第一次测试中,评估参与者的卧推一次最大重复量(1RM)。在随后的测试中,参与者以1RM的30%、50%、60%和70%完成两组三次重复的卧推。HUMAC和TENDO同时测量MV、PV和D,而HUMAC还测量重复持续时间(T)。使用组内相关系数(ICC)评估HUMAC的有效性以及MV、PV、D和T的组间和日间可靠性。与TENDO相比,HUMAC的有效性有限,因为在所有测量中ICC范围从差到好。在所有强度下,两种设备在MV、PV和D方面均观察到显著差异(<0.001)。所有强度和测量的组间可靠性都非常好,但在较高强度下,MV、PV和D的日间可靠性受到损害。与TENDO相比,HUMAC测量MV、PV和D的有效性有限。由于HUMAC能够可靠地评估MV、PV、D和T,包括组间和日间(高达1RM的60%),它可以作为基于速度训练的自动调节工具。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3264/11728576/aad060f2b485/ijes-17-7-1294f1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验