Suppr超能文献

Selective sensing of terbinafine hydrochloride using carbon-based electrodes: a green and sustainable electroanalytical method for pharmaceutical products.

作者信息

Borges Isabelle de Oliveira, Silva Lima Adriano Rogerio, Gomes Dos Santos Neto Antonio, Stulzer Hellen Karine, Jost Cristiane Luisa

机构信息

Universidade Federal de Santa Catarina, Departamento de Farmácia, 88040-900 Florianópolis, SC, Brazil.

ampere - Laboratório de Plataformas Eletroquímicas - Universidade Federal de Santa Catarina, Departamento de Química, 88040-900 Florianópolis, SC, Brazil.

出版信息

Anal Methods. 2025 Feb 13;17(7):1658-1669. doi: 10.1039/d4ay02151g.

Abstract

Terbinafine hydrochloride (TBF) is a broad-spectrum antifungal used to treat various dermatophyte infections affecting the skin, hair, and nails. Accurate, sensitive, and affordable analytical methods are crucial for quantifying this drug. In this study, we report on the use of carbon-based electrodes for the electrochemical determination of TBF in pharmaceutical samples, including raw materials and tablets. Notably, for the first time in the literature, we employ screen-printed carbon electrodes (SPCE) for TBF quantification. Additionally, glassy carbon electrodes (GCE) were used to explore the redox behavior of the analyte. Electrochemical performance was evaluated and compared using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Optimized conditions of supporting electrolyte and scan rate studies revealed that the oxidation of TBF involves an equal exchange of protons and electrons. For the GCE, the oxidation process was found to be irreversible, controlled by both diffusion and adsorption, while for the SPCE, it was irreversible and diffusion-controlled. Square wave voltammetry (SWV) was optimized for both electrodes to enhance sensitivity. For SPCE, the calibration curve ranged from 5 to 100 μg mL, with an LOD of 1.48 μg mL using a single drop of sample. The calibration curve for GCE was constructed between 2.5 and 30 μg mL, with a limit of detection (LOD) of 0.072 μg mL. TBF quantification was performed on raw material samples from various suppliers and tablet forms using external calibration with a recovery range within 90-110%. Analysis of the data reveals that the voltammetric method's accuracy aligns well with the chromatographic approach based on high performance liquid chromatography (HPLC). Furthermore, the proposed methodology demonstrated outstanding sustainability, achieving a score of 0.91 in Green Analytical Chemistry (GAC) criteria. Our novel approach combines high analytical efficiency with a reduced environmental impact, establishing itself as a green, cost-effective, and accurate alternative for TBF sensing.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验