Suppr超能文献

与动态对比增强磁共振成像相比,使用体素内不相干运动成像评估子宫肌瘤中的血流情况。

Assessing blood flow in uterine fibroids using intravoxel incoherent motion imaging compared with dynamic contrast-enhanced MRI.

作者信息

Sainio Teija, Saunavaara Jani, Komar Gaber, Viitala Antti, Otonkoski Saara, Joronen Kirsi, Perheentupa Antti, Sequeiros Roberto Blanco

机构信息

Department of Medical Physics, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland.

Department of Radiology, Turku University Hospital and University of Turku, Kiinamyllynkatu 4-8, Turku, 20521, Finland.

出版信息

Sci Rep. 2025 Jan 23;15(1):2980. doi: 10.1038/s41598-024-83739-z.

Abstract

To assess the utility of IVIM parameters in evaluating uterine fibroid blood flow compared to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) derived blood flow. Sixteen premenopausal women with uterine fibroids were enrolled in this prospective study. Pelvic MRI scans were obtained for each subject, both with and without continuous intravenous infusion of oxytocin, known to decrease significantly uterine fibroid blood flow, to assess the changes in blood flow of uterine fibroids. IVIM and DCE analyses were conducted using separate dedicated software. The bi-exponential IVIM model was used to estimate perfusion fraction (f), pseudo-diffusion coefficient (D*), and diffusion coefficient (D). DCE blood flow values were derived via T1 perfusion deconvolution arithmetic, utilizing a first pass of an AIF curve. The correlation between the parameters were analyzed by Spearman's rank correlation analysis due to small sample size. Means of the parameters were compared with a nonparametric Wilcoxon sign rank method for each pair. Statistically significant positive correlations were found between perfusion fraction values and DCE blood flow values with oxytocin (Spearson's ρ = 0.78, p = 0.0004), and between fD* values and DCE blood flow values with oxytocin (Spearson's ρ = 0.64, p = 0.0071). Significant differences in blood flow were detected across most IVIM parameters: f, D*, and fD* (p < 0.001, p = 0.0027, and p = 0.0002, respectively) when comparing the values without oxytocin and with oxytocin. IVIM imaging shows promise for assessing blood flow in uterine fibroids.

摘要

为了评估体素内不相干运动(IVIM)参数在评估子宫肌瘤血流方面的效用,并与动态对比增强磁共振成像(DCE-MRI)得出的血流结果进行比较。16名患有子宫肌瘤的绝经前女性参与了这项前瞻性研究。对每位受试者进行盆腔MRI扫描,分别在持续静脉输注催产素(已知其可显著降低子宫肌瘤血流)前后进行,以评估子宫肌瘤血流的变化。使用单独的专用软件进行IVIM和DCE分析。采用双指数IVIM模型来估计灌注分数(f)、伪扩散系数(D*)和扩散系数(D)。DCE血流值通过T1灌注反卷积算法,利用动脉输入函数(AIF)曲线的首次通过来得出。由于样本量较小,通过Spearman秩相关分析来分析参数之间的相关性。对于每一对参数,采用非参数Wilcoxon符号秩检验方法比较其均值。结果发现,灌注分数值与使用催产素时的DCE血流值之间存在统计学上显著的正相关(Spearson相关系数ρ = 0.78,p = 0.0004),fD值与使用催产素时的DCE血流值之间也存在显著正相关(Spearson相关系数ρ = 0.64,p = 0.0071)。在比较未使用催产素和使用催产素时的值时,在大多数IVIM参数(f、D和fD*)中均检测到血流存在显著差异(分别为p < 0.001、p = 0.0027和p = 0.0002)。IVIM成像在评估子宫肌瘤血流方面显示出前景。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ffa8/11758379/56d5da36e2cc/41598_2024_83739_Fig1a_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验