Suppr超能文献

使用超短回波时间(UTE)磁共振成像进行肌腱评估:一项系统评价。

Tendon evaluation with ultrashort Echo Time (UTE) MRI: A Systematic Review.

作者信息

Malhi Bhavsimran Singh, Jang Hyungseok, Malhi Manharjot Singh, Berry David B, Jerban Saeed

机构信息

Department of Radiology, University of California, San Diego, San Diego, CA, United States.

Department of Orthopedic Surgery, Indus Hospital, Mohali, India.

出版信息

Front Musculoskelet Disord. 2024;2. doi: 10.3389/fmscd.2024.1324050. Epub 2024 Mar 14.

Abstract

Tendon disease ranks among the leading reasons patients consult their general practitioners, comprising approximately one-third of musculoskeletal appointments. Magnetic resonance imaging (MRI) is regarded as the gold standard for assessing tendons. Due to their short transverse relaxation time (T2), Tendons show up as a signal void in conventional MRI scans, which employ sequences with echo times (TEs) around several milliseconds. Ultrashort echo time (UTE) sequences utilize TEs that are 100-1,000 times shorter than those used in conventional sequences. This enables the direct visualization of tendons and assessment of their relaxation times, which is the basis for quantitative MRI. A systematic review was conducted on publications after 1990 in Google Scholar and PubMed databases. The search terms "ultrashort echo time," "tendon," and "UTE" were used to identify studies related to this investigation. This review discussed the current knowledge in quantitative UTE-MRI imaging of tendons. Quantitative UTE-T1, UTE-T2*, UTE-MT, and UTE-T1ρ techniques were described, and their reported applications in the literature were summarized in this review. We also discussed the advantages and challenges of these techniques and how these quantitative biomarkers may change in response to tendon pathology.

摘要

肌腱疾病是患者咨询全科医生的主要原因之一,约占肌肉骨骼疾病门诊量的三分之一。磁共振成像(MRI)被视为评估肌腱的金标准。由于肌腱的横向弛豫时间(T2)较短,在采用回波时间(TE)约为几毫秒的序列的传统MRI扫描中,肌腱表现为信号缺失。超短回波时间(UTE)序列使用的TE比传统序列短100至1000倍。这使得能够直接观察肌腱并评估其弛豫时间,这是定量MRI的基础。我们在谷歌学术和PubMed数据库中对1990年以后的出版物进行了系统综述。使用“超短回波时间”“肌腱”和“UTE”等检索词来确定与本研究相关的研究。本综述讨论了肌腱定量UTE-MRI成像的当前知识。描述了定量UTE-T1、UTE-T2*、UTE-MT和UTE-T1ρ技术,并在本综述中总结了它们在文献中报道的应用。我们还讨论了这些技术的优点和挑战,以及这些定量生物标志物如何因肌腱病理变化而改变。

相似文献

9
UTE imaging in the musculoskeletal system.肌肉骨骼系统中的UTE成像。
J Magn Reson Imaging. 2015 Apr;41(4):870-83. doi: 10.1002/jmri.24713. Epub 2014 Jul 16.

本文引用的文献

6
On the fat saturation effect in quantitative ultrashort TE MR imaging.定量超短 TE MR 成像中的脂肪饱和效应。
Magn Reson Med. 2022 May;87(5):2388-2397. doi: 10.1002/mrm.29149. Epub 2022 Jan 5.
8
Achilles Tendinopathy: Evaluation, Rehabilitation, and Prevention.跟腱病:评估、康复和预防。
Curr Sports Med Rep. 2021 Jun 1;20(6):327-334. doi: 10.1249/JSR.0000000000000855.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验