Suppr超能文献

Detection of coronary artery disease by two-dimensional echocardiography and transesophageal atrial pacing.

作者信息

Iliceto S, Sorino M, D'Ambrosio G, Papa A, Favale S, Biasco G, Rizzon P

出版信息

J Am Coll Cardiol. 1985 May;5(5):1188-97. doi: 10.1016/s0735-1097(85)80024-3.

Abstract

Two-dimensional echocardiography was performed at rest and during rapid transesophageal atrial pacing in 85 patients undergoing coronary arteriography for evaluation of chest pain. Transesophageal atrial pacing was performed with 10 ms pulses of 6 to 27 mA intensity; the rate was progressively increased up to 150 beats/min. Four patients were excluded: two because atrial capture was not achieved and two because of chest discomfort induced during transesophageal atrial pacing. Of the remaining 81 patients, 56 had significant coronary artery disease (greater than or equal to 75% stenosis of at least one major coronary vessel) and 25 had no significant coronary artery disease; 25 of the 56 patients with coronary artery disease had no wall motion abnormalities at rest. The test was considered positive if wall motion abnormalities were detected during pacing. Wall motion abnormalities occurred in 3 of 25 patients without coronary artery disease (specificity 88%) and in 51 of 56 patients with coronary artery disease (sensitivity 91%). Wall motion abnormalities developed in 20 of the 25 patients with coronary artery disease and normal regional wall motion at rest (sensitivity 80%); sensitivity for one, two and three vessel disease was 85% (17 of 20 patients), 94% (15 of 16 patients) and 95% (19 of 20 patients), respectively. In patients without coronary artery disease, wall motion score was 18 at rest and 17.7 +/- 0.9 during pacing (p = NS). In patients with coronary artery disease, wall motion score decreased from 15.2 +/- 3.6 at rest to 11.6 +/- 4.1 during pacing (p less than 0.001). In patients with coronary artery disease and normal regional wall motion at rest, wall motion score decreased from 18 at rest to 14.4 +/- 3.1 during pacing (p less than 0.001). Thus, two-dimensional echocardiography during transesophageal atrial pacing appears both sensitive and specific in detecting patients with coronary artery disease. This new procedure is a feasible and reliable alternative to exercise two-dimensional echocardiography.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验