Chapman P D, Doyle T P, Troup P J, Gross C M, Wann L S

出版信息

Circulation. 1984 Sep;70(3):445-50. doi: 10.1161/01.cir.70.3.445.

Abstract

We performed two-dimensional echocardiography in 19 patients with significant coronary artery disease and in six normal volunteers at rest and during transesophageal atrial pacing. Technically adequate resting echocardiograms were obtained in 18 of the 19 patients and in all six normal volunteers. In two subjects, atrial capture was not possible, and in one subject, discomfort from the pacing at the beginning of the study precluded its completion. In all subjects (n = 21) who completed the protocol satisfactory two-dimensional echocardiograms were obtained during pacing. Wall motion was normal at rest and during atrial pacing in five normal volunteers. New transient wall motion abnormalities developed in 13 of the 16 patients during pacing. Twelve of the 13 patients had significant coronary lesions in the coronary arteries supplying the abnormal wall segment. Only three of the patients developed significant ST segment depression during pacing. We conclude that stress echocardiography with transesophageal atrial pacing is safe and practical and can be used in patients who cannot perform dynamic exercise, this technique can detect ischemic segmental wall motion abnormalities corresponding to the distribution of coronary arterial obstruction, and the technique provides high-quality echocardiographic images during stress and thus may expand the usefulness of resting two-dimensional echocardiography in patients who have ischemic heart disease.

摘要

我们对19例患有严重冠状动脉疾病的患者和6名正常志愿者在静息状态及经食管心房起搏过程中进行了二维超声心动图检查。19例患者中有18例以及所有6名正常志愿者均获得了技术上足够的静息超声心动图。在两名受试者中无法实现心房夺获,在一名受试者中,研究开始时起搏引起的不适使其无法完成检查。在所有圆满完成方案的受试者(n = 21)中,起搏期间均获得了二维超声心动图。5名正常志愿者在静息状态和心房起搏期间壁运动正常。16例患者中有13例在起搏过程中出现了新的短暂性壁运动异常。13例患者中有12例在供应异常壁段的冠状动脉中有明显的冠状动脉病变。只有3例患者在起搏期间出现了明显的ST段压低。我们得出结论,经食管心房起搏负荷超声心动图是安全可行的,可用于无法进行动态运动的患者,该技术可检测出与冠状动脉阻塞分布相对应的缺血性节段性壁运动异常,并且该技术在负荷状态下可提供高质量的超声心动图图像,因此可能会扩大静息二维超声心动图在缺血性心脏病患者中的应用价值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验