Gupta Divya, Shaw Amar K, Gaikwad Ashwini, Kale Pallavi, Deshpande Sneha M, Gachake Arti
Conservative Dentistry and Endodontics, MA Rangoonwala College of Dental Sciences & Research Centre, Pune, IND.
Public Health Dentistry, Bharati Vidyapeeth (Deemed to be) University Dental College and Hospital, Pune, IND.
Cureus. 2025 Jan 2;17(1):e76820. doi: 10.7759/cureus.76820. eCollection 2025 Jan.
This review was performed to evaluate the diagnostic accuracy of pulse oximetry (PO) in patients with apical periodontitis (AP) or undergoing an endodontic treatment. Preferred Reporting Items for Systematic Reviews and Meta-Analysis-Diagnostic Test Accuracy (PRISMA-DTA) checklist was followed to carry out this review. The diagnostic potential of pulse oximetry for pulp vitality status was studied through databases like PubMed, Google Scholar, EBSCOhost from 2000 to 2024. Extraction or manual calculation of true-positive, false-positive, true-negative, false-negative, sensitivity, and specificity values were done. Quality assessment of diagnostic accuracy studies (QUADAS)-2 tool and RevMan ver. 5.3 qualitatively assessed the included studies. The included seven studies evaluated 654 teeth and reported a low risk of bias (ROB). The included studies evaluated the reliability, efficacy, and diagnostic ability of PO and compared it to other conventional pulp vitality and sensitivity tests like a cold test, thermal test, electric pulp test (EPT), spray, and rubber cups. Its overall sensitivity ranged from 81-100% (mean 95%) and overall specificity ranged from 94-100% (mean 99%). It was concluded that pulse oximetry overall is more reliable, superior, effective and has overall diagnostic efficacy in detecting the target condition compared to other conventional modalities.
本综述旨在评估脉搏血氧饱和度测定法(PO)在根尖周炎(AP)患者或接受牙髓治疗患者中的诊断准确性。本综述遵循系统评价和Meta分析-诊断试验准确性(PRISMA-DTA)清单进行。通过PubMed、谷歌学术、EBSCOhost等数据库,研究了2000年至2024年期间脉搏血氧饱和度测定法对牙髓活力状态的诊断潜力。提取或手动计算真阳性、假阳性、真阴性、假阴性、敏感性和特异性值。使用诊断准确性研究质量评估(QUADAS)-2工具和RevMan 5.3版对纳入研究进行定性评估。纳入的七项研究评估了654颗牙齿,报告的偏倚风险较低。纳入的研究评估了PO的可靠性、有效性和诊断能力,并将其与其他传统的牙髓活力和敏感性测试(如冷诊、热诊、牙髓电活力测试(EPT)、喷雾和橡皮杯测试)进行了比较。其总体敏感性范围为81%-100%(平均95%),总体特异性范围为94%-100%(平均99%)。得出的结论是,与其他传统方法相比,脉搏血氧饱和度测定法总体上更可靠、更优越、更有效,并且在检测目标疾病方面具有总体诊断效力。