McLaren M I, Fleming J S, Walmsley B H, Ackery D M, Taylor I, Karran S J
Br J Surg. 1985 May;72(5):394-6. doi: 10.1002/bjs.1800720520.
Dynamic liver scanning using 99mTc sulphur colloid has been used in assessing 41 patients with cirrhosis and the data compared with 33 control subjects. The mesenteric fraction (MF) was significantly reduced in cirrhotics (0.30 +/- 0.17) compared with controls (0.58 +/- 0.09), P less than 0.001. The liver: spleen ratio (L:S) was also significantly different (1.6 +/- 0.95 compared with 4.9 +/- 1.4), P less than 0.001. Those patients who had undergone a recent variceal bleed had values less than patients who had not bled. Dynamic scintigraphy may be of value in monitoring the progress of disease and response to treatment.
使用99mTc硫胶体进行动态肝脏扫描,已用于评估41例肝硬化患者,并将数据与33名对照受试者进行比较。与对照组(0.58±0.09)相比,肝硬化患者的肠系膜分数(MF)显著降低(0.30±0.17),P<0.001。肝脾比(L:S)也有显著差异(分别为1.6±0.95和4.9±1.4),P<0.001。近期发生过静脉曲张出血的患者的值低于未出血的患者。动态闪烁扫描在监测疾病进展和治疗反应方面可能具有价值。