Adnan Atif, Chen Haodong, Rakha Allah, Tao Le, Shen Qu, Linli Chen, Zexiang Shao, Jiajia Guo, Minghao Shi, Alghafri Rashed, Novroski Nicole, Coman Cristina, Wang Chuan-Chao
Department of Anthropology and Ethnology, Institute of Anthropology, School of Sociology and Anthropology, Xiamen University, Xiamen, Fujian Province, 361000, China.
Department of Forensic Sciences, University of Health Sciences, Lahore, 54000, Pakistan.
Int J Legal Med. 2025 May;139(3):1069-1080. doi: 10.1007/s00414-025-03443-z. Epub 2025 Feb 18.
The necessity for developing the AGCU EX-38 typing system arises from the ever-increasing demand for more accurate and comprehensive forensic tools. Traditional kits with fewer STRs often fall short in complex cases requiring higher resolution. The AGCU EX-38 typing system incorporates 35 autosomal STRs, including extended CODIS loci as well as additional non-CODIS loci (D6S1043, D19S3045, D3S3045, D7S3048, D11S2368, D4S2366, D8S1132, D15S659, Penta D, Penta E, D6S447, D3S1744, D14S608, D18S535). This combination of CODIS and non-CODIS markers provides a significant advantage, particularly in complex kinship analyses such as half-sibship cases. This six-dye kit encompasses 38 loci, with a maximum amplicon size of 550 base pairs (bp), and features nine STRs within 200 bp and 14 STRs within 300 bp, offering unparalleled coverage and sensitivity. The AGCU EX-38 typing system is the only available kit on the market containing 35 autosomal STRs with six-dye chemistry, making it a unique and invaluable resource for forensic laboratories. This configuration allows for higher resolution and superior performance in cases with degraded or mixed DNA samples. In this study, we report the results of the developmental validation study, which followed the SWGDAM (Scientific Working Group on DNA Analysis Methods) guidelines. The data includes PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design and demonstrate the kit's robustness, reliability, and suitability for genetic identification and population studies.
开发AGCU EX-38分型系统的必要性源于对更准确、更全面的法医工具的需求不断增加。传统的短串联重复序列(STR)较少的试剂盒在需要更高分辨率的复杂案件中往往不足。AGCU EX-38分型系统包含35个常染色体STR,包括扩展的联合DNA索引系统(CODIS)位点以及额外的非CODIS位点(D6S1043、D19S3045、D3S3045、D7S3048、D11S2368、D4S2366、D8S1132、D15S659、五核苷酸D、五核苷酸E、D6S447、D3S1744、D14S608、D18S535)。这种CODIS和非CODIS标记的组合具有显著优势,特别是在诸如半同胞关系案件等复杂的亲属关系分析中。这个六色试剂盒涵盖38个位点,最大扩增子大小为550碱基对(bp),并且在小于200bp的范围内有9个STR,在小于300bp的范围内有14个STR,提供了无与伦比的覆盖范围和灵敏度。AGCU EX-38分型系统是市场上唯一可用的包含35个常染色体STR且采用六色化学法的试剂盒,使其成为法医实验室独特且宝贵的资源。这种配置在DNA样本降解或混合的案件中具有更高的分辨率和卓越的性能。在本研究中,我们报告了遵循DNA分析方法科学工作组(SWGDAM)指南进行的开发验证研究的结果。数据包括基于聚合酶链反应(PCR)的研究、灵敏度、物种特异性、稳定性、精密度、可重复性和重复性、一致性、拖尾、DNA混合物以及模拟案件样本上的性能。结果验证了多重设计,并证明了该试剂盒的稳健性、可靠性以及在基因鉴定和群体研究中的适用性。