Suppr超能文献

圆锥角膜眼与正常近视眼的非角膜性眼内高阶像差

Non-corneal Intraocular Higher Order Aberrations in Eyes With Keratoconus Versus Normal Myopic Eyes.

作者信息

Kozhaya Karim, Mehanna Carl-Joe, Asroui Lara, Bejjani Romy, Arba-Mosquera Samuel, Mousa Hazem M, Al-Ulloom Saleh Bahir, Awwad Shady T

出版信息

J Refract Surg. 2025 Mar;41(3):e189-e198. doi: 10.3928/1081597X-20250103-02. Epub 2025 Mar 1.

Abstract

PURPOSE

To evaluate and compare non-corneal intraocular higher order aberrations (HOAs) in keratoconic and normal myopic eyes.

METHODS

Eighty-eight keratoconic and 106 normal myopic eyes were examined using high-resolution (1) pyramidal ocular wavefront sensor PERAMIS (designed by CSO for SCHWIND eye-tech-solutions GmbH) and (2) anterior segment optical coherence tomography (AS-OCT) MS-39 (CSO). Intraocular HOAs were calculated by subtracting the total corneal aberrations measured by the AS-OCT from the total ocular aberrations measured by the pyramidal aberrometer. Aberrations were reported at an optical zone of 5.5 mm and were referenced to the pupil center.

RESULTS

Every component of absolute intraocular HOAs was larger in keratoconic eyes than in myopic eyes in regard to magnitude and vertical and horizontal components ( < .05). Intraocular HOAs were also more scattered in keratoconic eyes. For trefoil aberrations, the axes of total corneal and intraocular centroid were opposing, almost 60 degrees away in keratoconic eyes. This mirrored the difference in orientation between anterior and posterior corneal trefoil. For each of coma and trefoil, 15.9% of keratoconic and 0% of myopic eyes had intraocular aberrations of 0.50 diopters (D) or greater. A total of 3.4% of keratoconic eyes and 0% of myopic eyes had total intraocular HOAs of 1.00 D or greater (all < .05).

CONCLUSIONS

Intraocular HOAs in keratoconus are larger than in normal eyes and can either offset or support their total corneal counterparts. Intraocular HOAs should be computed and taken into consideration when planning customized corrections in eyes with keratoconus. .

摘要

目的

评估并比较圆锥角膜眼和正常近视眼的非角膜眼内高阶像差(HOAs)。

方法

使用高分辨率(1)锥面眼波前传感器PERAMIS(由CSO为SCHWIND眼科技解决方案有限公司设计)和(2)前段光学相干断层扫描(AS-OCT)MS-39(CSO)对88只圆锥角膜眼和106只正常近视眼进行检查。眼内HOAs通过从锥面像差仪测量的总眼像差中减去AS-OCT测量的总角膜像差来计算。像差报告的光学区为5.5mm,并以瞳孔中心为参考。

结果

就大小以及垂直和水平分量而言,圆锥角膜眼的绝对眼内HOAs的每个分量均大于近视眼(P<0.05)。圆锥角膜眼的眼内HOAs也更分散。对于三叶草像差,圆锥角膜眼中总角膜和眼内心形曲线的轴是相反的,相差近60度。这反映了前后角膜三叶草在方向上的差异。对于彗差和三叶草像差中的每一种,15.9%的圆锥角膜眼和0%的近视眼的眼内像差为0.50屈光度(D)或更高。共有3.4%的圆锥角膜眼和0%的近视眼的总眼内HOAs为1.00 D或更高(均P<0.05)。

结论

圆锥角膜眼的眼内HOAs大于正常眼,并且可以抵消或支持其对应的总角膜像差。在为圆锥角膜眼规划定制矫正时,应计算并考虑眼内HOAs。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验