Port S C, Oshima M, Ray G, McNamee P, Schmidt D H
J Am Coll Cardiol. 1985 Jul;6(1):75-83. doi: 10.1016/s0735-1097(85)80256-4.
The sensitivity of the commonly used stress tests for the diagnosis of coronary artery disease was analyzed in 46 patients with significant occlusion (greater than or equal to 70% luminal diameter obstruction) of only one major coronary artery and no prior myocardial infarction. In all patients, thallium-201 perfusion imaging (both planar and seven-pinhole tomographic) and 12 lead electrocardiography were performed during the same graded treadmill exercise test and radionuclide angiography was performed during upright bicycle exercise. Exercise rate-pressure (double) product was 22,307 +/- 6,750 on the treadmill compared with 22,995 +/- 5,622 on the bicycle (p = NS). Exercise electrocardiograms were unequivocally abnormal in 24 patients (52%). Qualitative planar thallium images were abnormal in 42 patients (91%). Quantitative analysis of the tomographic thallium images were abnormal in 41 patients (89%). An exercise ejection fraction of less than 0.56 or a new wall motion abnormality was seen in 30 patients (65%). Results were similar for the right (n = 11) and left anterior descending (n = 28) coronary arteries while all tests but the planar thallium imaging showed a lower sensitivity for isolated circumflex artery disease (n = 7). The specificity of the tests was 72, 83, 89 and 72% for electrocardiography, planar thallium imaging, tomographic thallium imaging and radionuclide angiography, respectively. The results suggest that exercise thallium-201 perfusion imaging is the most sensitive noninvasive stress test for the diagnosis of single vessel coronary artery disease.
对46例仅一支主要冠状动脉存在严重阻塞(管腔直径阻塞大于或等于70%)且既往无心肌梗死的患者,分析了常用的用于诊断冠状动脉疾病的负荷试验的敏感性。所有患者在同一次分级运动平板试验中进行了铊-201灌注显像(平面显像和七针孔断层显像)及12导联心电图检查,并在直立自行车运动时进行了放射性核素血管造影。运动平板试验时的运动率压(双)乘积为22307±6750,而自行车运动时为22995±5622(p=无显著性差异)。24例患者(52%)运动心电图明确异常。42例患者(91%)定性平面铊显像异常。41例患者(89%)断层铊显像定量分析异常。30例患者(65%)出现运动射血分数小于0.56或新的室壁运动异常。右冠状动脉(n=11)和左前降支冠状动脉(n=28)的结果相似,而除平面铊显像外的所有检查对孤立性回旋支动脉疾病(n=7)的敏感性较低。心电图、平面铊显像、断层铊显像和放射性核素血管造影的检查特异性分别为72%、83%、89%和72%。结果提示,运动铊-201灌注显像是诊断单支冠状动脉疾病最敏感的无创负荷试验。