Valencia Sergio, Machado-Rivas Fedel, Avesta Arman, Barkovich Emil J, Cartmell Samuel C D, Warfield Simon K, Jaimes Camilo, Afacan Onur
Massachusetts General Hospital, Boston, USA.
Harvard Medical School, Boston, USA.
Pediatr Radiol. 2025 Mar 17. doi: 10.1007/s00247-025-06213-6.
T2*-weighted imaging at 7 T offers detailed visualization of brain structures, but image quality and artifacts depend on echo time (TE) adjustments. Optimizing TE is crucial for tissue contrast and artifact minimization.
To evaluate the impact of TE on tissue contrast and image quality in T2*-weighted sequences at 7 T in adolescents and young adults.
Ten adolescent and young adult patients underwent 7-T MRI with multi-echo T2*-weighted sequences. Six TEs (8.1 ms to 36 ms) were acquired. Signal contrast ratios (CR) for seven brain regions-caudate nuclei, corpus callosum genu, frontal cortex, cortical veins, globi pallidi, medullary veins, and left optic radiation-were analyzed. Two blinded neuroradiologists assessed image quality and artifact severity using a 4-point Likert scale (IQS). Statistical trends were analyzed using the Jonckheere-Terpstra test. A P-value < 0.05 was considered statistically significant.
The study cohort consisted of 4 male and 6 females; the median age of the patients was 16 years (range 15-23 years). CR increased significantly with higher TEs for most regions except the caudate, where CR decreased (P < 0.05). Longer TEs led to greater artifact severity in the brainstem, temporal, occipital, and frontal lobes (P < 0.02), but not in parietal lobes (P > 0.05). Kappa agreement for IQS was 0.76.
TE significantly affects contrast and artifacts in 7-T T2*-weighted imaging. TEs between 20 and 30 ms offer the best balance between tissue contrast and artifact severity, optimizing image quality for clinical and research applications.
7T场强下的T2*加权成像能够对脑结构进行详细可视化,但图像质量和伪影取决于回波时间(TE)调整。优化TE对于组织对比度和最小化伪影至关重要。
评估TE对青少年和青年成人7T场强下T2*加权序列中组织对比度和图像质量的影响。
10例青少年和青年成人患者接受了7T磁共振成像,采用多回波T2*加权序列。采集了6个TE值(8.1毫秒至36毫秒)。分析了7个脑区(尾状核、胼胝体膝部、额叶皮质、皮质静脉、苍白球、髓质静脉和左侧视辐射)的信号对比率(CR)。两名盲法神经放射科医生使用4分李克特量表(IQS)评估图像质量和伪影严重程度。使用琼克尔-特普斯特拉检验分析统计趋势。P值<0.05被认为具有统计学意义。
研究队列包括4名男性和6名女性;患者的中位年龄为16岁(范围15 - 23岁)。除尾状核外,大多数区域的CR随TE值升高而显著增加,尾状核的CR则下降(P<0.05)。较长的TE导致脑干、颞叶、枕叶和额叶的伪影严重程度增加(P<0.02),但顶叶未增加(P>0.05)。IQS的kappa一致性为0.76。
TE在7T T2*加权成像中显著影响对比度和伪影。20至30毫秒之间的TE在组织对比度和伪影严重程度之间提供了最佳平衡,优化了临床和研究应用的图像质量。