Suppr超能文献

热电堆传感器显示,重度抑郁症患者在上午9点时手腕外周皮肤的平均温度比健康人低2.9摄氏度。

A Thermopile Sensor Revealed That the Average Peripheral Wrist Skin Temperature of Patients with Major Depressive Disorder at 09:00 Is 2.9 °C Lower than That of Healthy People.

作者信息

Watanabe Keisuke, Sato Shohei, Obara Yusuke, Kariya Nobutoshi, Shinba Toshikazu, Matsui Takemi

机构信息

Department of Electrical Engineering and Computer Science, Graduate School of Systems Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan.

Maynds Tower Mental Clinic, Tokyo 151-0053, Japan.

出版信息

Sensors (Basel). 2025 Mar 5;25(5):1582. doi: 10.3390/s25051582.

Abstract

Many patients with major depressive disorder (MDD) feel worse in the morning than in the evening. To clarify the differences in morning physiological characteristics between patients with MDD and healthy participants, a wearable device that measures peripheral wrist skin temperature and heart rate (HR) was adopted. The device incorporates a thermopile sensor to measure peripheral wrist skin temperature using infrared radiation emitted from the skin surface. In total, 30 patients diagnosed with MDD and 24 healthy individuals were recruited. From 00:00 to 12:00, participants wore a wrist-worn device on their non-dominant hand. It was discovered that, at 09:00, the average peripheral wrist skin temperature of patients with MDD was significantly lower (by 0.1% [2.9 °C]) than that of healthy individuals. The dramatic decrease in morning (09:00) peripheral wrist skin temperature in patients with MDD can be attributed to their morning sympathetic surge and peripheral vascular contraction. The average HR of patients with MDD was significantly higher (by 1% [17 beats/min]) than that of healthy controls. Regression analysis, including peripheral wrist skin temperature and HR at 09:00, showed 83.3% sensitivity and a negative predictive value of 76.2%. The potential impact of these results appears promising for future preliminary morning MDD screening.

摘要

许多重度抑郁症(MDD)患者早晨感觉比晚上更糟。为了阐明MDD患者与健康参与者早晨生理特征的差异,采用了一种可穿戴设备来测量外周手腕皮肤温度和心率(HR)。该设备集成了一个热电堆传感器,利用皮肤表面发出的红外辐射来测量外周手腕皮肤温度。总共招募了30名被诊断为MDD的患者和24名健康个体。从00:00到12:00,参与者在非优势手上佩戴腕戴式设备。研究发现,在09:00时,MDD患者的平均外周手腕皮肤温度显著低于健康个体(低0.1%[2.9℃])。MDD患者早晨(09:00)外周手腕皮肤温度的显著下降可归因于其早晨交感神经兴奋和外周血管收缩。MDD患者的平均心率显著高于健康对照组(高1%[17次/分钟])。包括09:00时外周手腕皮肤温度和心率的回归分析显示,敏感性为83.3%,阴性预测值为76.2%。这些结果的潜在影响对于未来早晨MDD的初步筛查似乎很有前景。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/37b1/11902303/564b90b550b4/sensors-25-01582-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验