To assess eye movements during reading in individuals with central vision loss using eye-tracking technology and an ad-hoc calibration method.
This pilot case control study included 17 participants (61.7 ± 8.8 years), 12 women and 5 men) and 17 controls, matched for age and sex. Two ad hoc computer-based tests were administered to analyze eye movements during a single-letter reading task and continuous reading task, measured using a 60 Hz eye-tracking device.
Individuals with central vision loss showed differences from the control group, with an increase in the number of fixations, saccadic movements, and regressions, whereas the amplitude and speed of saccades were lower. This resulted in longer reading times in the study group.
The results revealed lower performance in eye movements skills during reading tasks in patients with central vision loss. Eye-tracking devices allow the objective binocular assessment of eye movements during reading tasks. Our ad-hoc calibration method ensured minimal data loss and high validity, enhancing the reliability of the assessments. This information can be used to develop optimal and personalized functional and visual rehabilitation programs.
使用眼动追踪技术和一种临时校准方法评估中心视力丧失个体在阅读过程中的眼动情况。
这项初步病例对照研究纳入了17名参与者(年龄61.7±8.8岁,12名女性和5名男性)以及17名年龄和性别匹配的对照者。进行了两项基于计算机的临时测试,以分析在单字母阅读任务和连续阅读任务期间的眼动情况,使用60赫兹的眼动追踪设备进行测量。
中心视力丧失个体与对照组存在差异,注视次数、扫视运动次数和回视次数增加,而扫视的幅度和速度较低。这导致研究组的阅读时间更长。
结果显示中心视力丧失患者在阅读任务期间的眼动技能表现较差。眼动追踪设备能够对阅读任务期间的眼动进行客观的双眼评估。我们的临时校准方法确保了最小的数据丢失和高有效性,提高了评估的可靠性。这些信息可用于制定最佳的个性化功能和视觉康复方案。