Early diagnosis of colorectal cancer (CRC), a malignant tumor with high incidence and mortality rates worldwide, can significantly reduce both its incidence and mortality. Among cancer diagnostic methods, tumor fluorescence imaging provides a non-invasive approach, eliminating the need for tissue biopsy and minimizing patient discomfort. In this study, we identified a water-soluble quinolinium molecular fluorescent probe (CYI), which exhibits a dose-dependent quantum yield in PBS solution, reaching 5.96% at a concentration of 20 µM. The results demonstrated that CYI selectively enters CRC cells and maintains stable fluorescence intensity within them by specifically targeting the mitochondria and lysosomes, leading to probe accumulation and enhanced intracellular fluorescence. Importantly, toxicity assays at both the cellular and animal levels confirmed that CYI is highly biocompatible at fluorescence imaging doses, with no toxic effects observed in normal colorectal cells or organisms. This study identifies CYI as a water-soluble molecular fluorescent probe with a high biosafety profile, excellent imaging stability, and preferential uptake by CRC cells, demonstrating strong potential for early CRC screening and in vivo monitoring.
结直肠癌(CRC)是一种在全球范围内发病率和死亡率都很高的恶性肿瘤,其早期诊断可以显著降低发病率和死亡率。在癌症诊断方法中,肿瘤荧光成像提供了一种非侵入性方法,无需组织活检,可将患者不适降至最低。在本研究中,我们鉴定了一种水溶性喹啉鎓分子荧光探针(CYI),它在PBS溶液中表现出剂量依赖性量子产率,在浓度为20 µM时达到5.96%。结果表明,CYI通过特异性靶向线粒体和溶酶体选择性进入CRC细胞,并在细胞内保持稳定的荧光强度,导致探针积累和细胞内荧光增强。重要的是,细胞和动物水平的毒性试验证实,CYI在荧光成像剂量下具有高度生物相容性,在正常结肠直肠细胞或生物体中未观察到毒性作用。本研究确定CYI是一种具有高生物安全性、优异成像稳定性且被CRC细胞优先摄取的水溶性分子荧光探针,显示出在CRC早期筛查和体内监测方面的强大潜力。