弹性超声成像与18F-FDG PET/CT在鉴别涎腺良恶性肿瘤中的对比分析:一项系统评价和荟萃分析

Comparative analysis of elastosonography and 18 F-FDG PET/CT in differentiating benign and malignant salivary gland tumors: a systematic review and meta-analysis.

作者信息

Jiang Zhibing, Guo Jinjing, Hu Liang, Zhao Xinran, Yang Siyu, Zhong Xiaokang, Lei Xiaoming, Tang Qun

机构信息

Medical School, Hunan University of Chinese Medicine, Changsha, 410208, Hunan Province, China.

出版信息

BMC Oral Health. 2025 Apr 1;25(1):464. doi: 10.1186/s12903-025-05809-6.

Abstract

PURPOSE

We conducted a systematic review and meta-analysis to assess and compare the diagnostic performance of elastosonography and 18 F-FDG PET/CT in differentiating between benign and malignant salivary gland tumors.

METHODS

Using PICOS criteria, experimental and observational research evaluating elastosonography or 18 F-FDG PET/CT for differentiating benign and malignant salivary gland tumors were included. A systematic search was conducted across PubMed, Embase, Web of Science, Scopus, Cochrane Library, and CINAHL, initially in July 2024 and updated in February 2025. A manual search for relevant gray literature was also performed. Data extraction and risk of bias assessment using QUADAS-2 were conducted independently by reviewers.

RESULTS

A total of 26 studies with 1609 patients were included in the analysis. The pooled sensitivity of elastosonography and 18 F-FDG PET/CT in the differential diagnosis of benign and malignant salivary gland tumors were 0.75 (95% CI 0.65-0.84) and 0.84 (95% CI 0.78-0.90), specificity was 0.79 (95% CI 0.69-0.87) and 0.85 (95% CI 0.69-0.96), respectively. The area under the curve (AUC) for elastosonography and 18 F-FDG PET/CT were 0.83 and 0.92 and there is a statistical difference between the two imaging modalities (Z = 2.77, P < 0.01). Fagan nomogram indicated that when the pre-test probability was set at 20%, the post-test probability for elastosonography and 18 F-FDG PET/CT could increase to 50% and 65%.

CONCLUSION

In differentiating between benign and malignant salivary gland tumors, 18 F-FDG PET/CT exhibits a superior AUC compared to elastosonography, suggesting that, despite its current limited use in the initial workup of salivary gland tumors, there may be a strong argument for its increased adoption in clinical practice. Nevertheless, it is crucial to note that the findings of this meta-analysis rely on studies with limited sample sizes. More extensive prospective studies are warranted to validate these results further.

摘要

目的

我们进行了一项系统评价和荟萃分析,以评估和比较弹性超声和18F-FDG PET/CT在鉴别涎腺肿瘤良恶性方面的诊断性能。

方法

采用PICOS标准,纳入评估弹性超声或18F-FDG PET/CT鉴别涎腺肿瘤良恶性的实验性和观察性研究。最初于2024年7月在PubMed、Embase、Web of Science、Scopus、Cochrane图书馆和CINAHL进行了系统检索,并于2025年2月更新。还对手工检索相关灰色文献。由 reviewers 独立进行数据提取和使用QUADAS-2的偏倚风险评估。

结果

共有26项研究、1609例患者纳入分析。弹性超声和18F-FDG PET/CT在涎腺肿瘤良恶性鉴别诊断中的合并敏感度分别为0.75(95%CI 0.65-0.84)和0.84(95%CI 0.78-0.90),特异度分别为0.79(95%CI 0.69-0.87)和0.85(95%CI 0.69-0.96)。弹性超声和18F-FDG PET/CT的曲线下面积(AUC)分别为0.83和0.92,两种成像方式之间存在统计学差异(Z = 2.77,P < 0.01)。Fagan列线图表明,当检验前概率设定为20%时,弹性超声和18F-FDG PET/CT的检验后概率可分别提高到50%和65%。

结论

在鉴别涎腺肿瘤良恶性方面,18F-FDG PET/CT的AUC优于弹性超声,这表明,尽管目前其在涎腺肿瘤初始检查中的应用有限,但在临床实践中增加其应用可能有充分的理由。然而,必须注意的是,这项荟萃分析的结果依赖于样本量有限的研究。需要更广泛的前瞻性研究来进一步验证这些结果。