Suppr超能文献

F-FDG PET/CT 影像组学在淋巴瘤中的诊断价值:一项系统评价与Meta分析

Diagnostic Value of F-FDG PET/CT Radiomics in Lymphoma: A Systematic Review and Meta-Analysis.

作者信息

Liu Chaoying, Zhao Jun, Zhang Heng, Ni Xinye

机构信息

Department of Medical Equipment, the Third Affiliated Hospital of Nanjing Medical University, The Second People's Hospital of Changzhou, Changzhou, Jiangsu, China.

Jiangsu Province Engineering Research Center of Medical Physics, Changzhou, Jiangsu, China.

出版信息

Technol Cancer Res Treat. 2025 Jan-Dec;24:15330338251342860. doi: 10.1177/15330338251342860. Epub 2025 May 21.

Abstract

IntroductionVarious machine learning models and features have been proposed for lymphoma diagnosis using F-fluorodeoxyglucose (F-FDG) PET/CT radiomics. This research aimed to systematically evaluate the diagnostic value of F-FDG PET/CT radiomics in lymphoma by conducting a meta-analysis.MethodsData from published studies regarding the diagnosis of lymphoma using F-FDG PET/CT radiomics, from January 2010 to July 2024, were gathered from PubMed, Web of Science, and the Cochrane Library. Following their separate searches and screenings of the literature, two researchers extracted data and assessed the caliber of all the included studies. The quality assessment involved the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2), the Radiomics Quality Score (RQS), and the METhodological RadiomICs Score (METRICS). The meta-analysis was conducted by using RevMan 5.4.1, R 4.4.0, and Stata 17.0 software. Six meta-regressions were conducted on study performance, considering sample size, image modality, region of interest (ROI) selection, ROI segmentation, radiomics mode, and algorithms.ResultsIn total, 20 studies classified as type 2a or above according to the Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis (TRIPOD) statement were included for this systematic review and meta-analysis. The studies achieved an average RQS of 13 (ranging from 10 to 17), accounting for 36.1% of the total points. The average METRICS score was 69.3% (ranging from 54.8% to 80.9%). The quality category of the studies is mainly "good". The results of our meta-analysis showed that the pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio with 95% confidence interval () were 0.82 (0.78, 0.88), 0.83 (0.76, 0.87), 4.7 (3.4, 6.6), 0.20 (0.15, 0.28) and 23 (13, 42), respectively. The area under the curve of the summary receiver operating characteristic curve was 0.90 (0.87, 0.92). The results of Spearman correlation analysis revealed no threshold effect among the studies ( = .423). Significant heterogeneity was observed among the studies (overall  = 83.7%; 95% : 76.0, 88.9;  < .01). Meta-regressions indicated that sample size and ROI selection contributed to the heterogeneity in SEN, while algorithms affected the heterogeneity in SPE ( < .05). Deeks' test confirmed there was no significant publication bias in all the included studies. The Fagan nomogram showed an absolute increase of 34% in the post-test probability following a positive test result.ConclusionThe results supported that F-FDG PET/CT radiomics has high diagnostic value for lymphoma. However, there is high heterogeneity among different studies. In the future, clinical practicality needs to be substantiated by more prospective studies with rigorous adherence to existing guidelines and multicentric validation.

摘要

引言

针对使用氟代脱氧葡萄糖(F-FDG)PET/CT影像组学进行淋巴瘤诊断,已经提出了各种机器学习模型和特征。本研究旨在通过进行荟萃分析,系统评估F-FDG PET/CT影像组学在淋巴瘤诊断中的价值。

方法

从2010年1月至2024年7月,从PubMed、Web of Science和Cochrane图书馆收集已发表的关于使用F-FDG PET/CT影像组学诊断淋巴瘤的研究数据。在各自对文献进行检索和筛选后,两名研究人员提取数据并评估所有纳入研究的质量。质量评估包括诊断准确性研究的质量评估2(QUADAS-2)、影像组学质量评分(RQS)和影像组学方法评分(METRICS)。使用RevMan 5.4.1、R 4.4.0和Stata 17.0软件进行荟萃分析。考虑样本量、图像模态、感兴趣区域(ROI)选择、ROI分割、影像组学模式和算法,对研究性能进行了六项荟萃回归分析。

结果

根据个体预后或诊断的多变量预测模型的透明报告(TRIPOD)声明,本系统评价和荟萃分析共纳入20项分类为2a型及以上的研究。这些研究的平均RQS为13分(范围为10至17分),占总分的36.1%。平均METRICS评分为69.3%(范围为54.8%至80.9%)。研究的质量类别主要为“良好”。我们的荟萃分析结果显示,合并敏感度(SEN)、特异度(SPE)、阳性似然比、阴性似然比和诊断比值比及其95%置信区间(CI)分别为0.82(0.78,0.88)、0.83(0.76,0.87)、4.7(3.4,6.6)、0.20(0.15,0.28)和23(13,42)。汇总受试者工作特征曲线下面积为0.90(0.87,0.92)。Spearman相关性分析结果显示,各研究之间无阈值效应(r = 0.423)。研究间观察到显著的异质性(总体I² = 83.7%;95%CI:76.0,88.9;P < 0.01)。荟萃回归分析表明,样本量和ROI选择导致SEN的异质性,而算法影响SPE的异质性(P < 0.05)。Deeks检验证实,所有纳入研究均无显著的发表偏倚。Fagan列线图显示,检测结果为阳性后,检测后概率绝对增加34%。

结论

结果支持F-FDG PET/CT影像组学对淋巴瘤具有较高的诊断价值。然而,不同研究之间存在高度异质性。未来,需要通过更严格遵循现有指南并进行多中心验证的前瞻性研究来证实其临床实用性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/226c/12099142/f6647e5a5419/10.1177_15330338251342860-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验