Suppr超能文献

人体视网膜血管中的血流速度和容积流量

Blood velocity and volumetric flow rate in human retinal vessels.

作者信息

Riva C E, Grunwald J E, Sinclair S H, Petrig B L

出版信息

Invest Ophthalmol Vis Sci. 1985 Aug;26(8):1124-32.

PMID:4019103
Abstract

The distributions of blood velocity and volumetric flow rate in individual vessels of the normal human retina were determined as a function of vessel diameter. The mean velocity of blood, Vmean, was calculated from the centerline velocity measured by bidirectional laser Doppler velocimetry (LDV). Volumetric flow rate was determined from Vmean and the vessel diameter, D, measured from monochromatic fundus photographs. Diameter of the arteries and veins at the site of the LDV measurements ranged from 39 to 134 microns and 64 to 177 microns, respectively. Flow velocity correlated with D (P less than 0.001 for both arteries and veins). Volumetric flow rate varied with D at a power of 2.76 +/- 0.16 for arteries and 2.84 +/- 0.12 for veins, in close agreement with Murray's law. Calculated from 12 eyes, the average total arterial and venous volumetric flow rates were 33 +/- 9.6 and 34 +/- 6.3 microliters/min, respectively. The good agreement between both flow rates suggests that the technique and the assumptions for calculating flow yield results that satisfy mass conservation. Total arterial and venous volumetric flow rates correlated with total arterial and venous vessel cross-section. Volumetric flow rate in the temporal retina was significantly greater than in the nasal retina, but the difference is likely to be due to the larger area of the temporal retina. No difference in flow rate was observed between the superior and inferior retinal hemispheres. Finally, blood velocity in the major retinal vessels measured under normal experimental conditions appears remarkably constant over short (hours) and long (months) periods of time.

摘要

已确定正常人类视网膜中各血管内血流速度和容积流量分布与血管直径的函数关系。血液平均速度Vmean通过双向激光多普勒测速法(LDV)测量的中心线速度计算得出。容积流量由Vmean和从单色眼底照片测量得到的血管直径D确定。LDV测量部位的动脉和静脉直径分别在39至134微米和64至177微米范围内。血流速度与D相关(动脉和静脉的P均小于0.001)。动脉的容积流量随D以2.76±0.16的幂变化,静脉则以2.84±0.12的幂变化,这与默里定律高度一致。根据12只眼睛计算,平均总动脉和静脉容积流量分别为33±9.6和34±6.3微升/分钟。两种流量之间的良好一致性表明,计算流量的技术和假设得出了满足质量守恒的结果。总动脉和静脉容积流量与总动脉和静脉血管横截面积相关。颞侧视网膜的容积流量显著大于鼻侧视网膜,但这种差异可能是由于颞侧视网膜面积较大所致。视网膜上下半球之间未观察到流量差异。最后,在正常实验条件下测量的主要视网膜血管中的血流速度在短时间(数小时)和长时间(数月)内均表现出显著的稳定性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验