Suppr超能文献

一种新型便携式眼科超声设备的性能验证

Performance Validation of a New Portable Ophthalmic Ultrasound Device.

作者信息

Pandya Dhanush P, Kannan Kiruthika, Venkataraju Kannan, Hansraj Saarang, Reddy Pappuru Rajeev, Das Taraprasad, Kondusamy Ravichandran, Sagadevan Jayasankar, Belenje Akash

机构信息

Srimati Kanuri Santhamma Centre for Vitreo-Retinal Diseases, Anant Bajaj Retina Institute, Kallam Anji Reddy Campus, LV Prasad Eye Institute, Hyderabad, IND.

Research and Development, Appasamy Associates Private Limited, Chennai, IND.

出版信息

Cureus. 2025 Mar 17;17(3):e80711. doi: 10.7759/cureus.80711. eCollection 2025 Mar.

Abstract

Purpose This study aimed to compare a new indigenous portable ophthalmic ultrasound device with an industry-standard multinational device for its accuracy, precision, and potential use in home care. Methods Axial and transverse images were compared for the same eye at the same visit using the India-made and multinational-made industry-standard devices for several common and rare vitreoretinal conditions in a large referral center in India. All images were obtained by the same optometrist on the same day using the India- and multinational-made devices in that sequence. Two third-year retina fellow investigators masked to the diagnosis and device analyzed the images for inter- and intra-observer accuracy of clinical diagnosis. The clinical diagnosis was compared with a senior vitreoretinal faculty member. Results The study included 118 eyes scanned once with each device. The overall accuracy was 88.9% for the portable India-made device and 85.5% for the multinational-made device. The inter-observer agreement and kappa were the same for the India-made and multinational-made devices; these were 91.52% and 0.83, respectively. The intra-observer agreement for various diagnoses for grader 1 was 95% (Cohen's kappa: 0.89) and for grader 2 was 93.3% (Cohen's kappa: 0.86). Conclusion The India-made portable ophthalmic ultrasound device was non-inferior to the multinational-made device in clinical utility. Its advantages were portability, lesser cost, and ease of use, which make the device more suitable for home eye care.

摘要

目的 本研究旨在比较一种新型国产便携式眼科超声设备与一款行业标准的跨国设备在准确性、精确性以及家庭护理中的潜在应用方面的差异。方法 在印度一家大型转诊中心,针对几种常见和罕见的玻璃体视网膜疾病,在同一次就诊时使用印度制造和跨国制造的行业标准设备对同一只眼睛的轴向和横向图像进行比较。所有图像均由同一名验光师在同一天按该顺序使用印度制造和跨国制造的设备获取。两名对诊断和设备不知情的三年级视网膜研究员分析图像,以评估临床诊断的观察者间和观察者内准确性。将临床诊断结果与一位资深玻璃体视网膜科教员进行比较。结果 该研究共纳入118只眼睛,每种设备各扫描一次。国产便携式设备的总体准确率为88.9%,跨国制造设备的总体准确率为85.5%。国产和跨国制造设备的观察者间一致性和kappa值相同;分别为91.52%和0.83。分级员1对各种诊断的观察者内一致性为95%(科恩kappa系数:0.89),分级员2为93.3%(科恩kappa系数:0.86)。结论 国产便携式眼科超声设备在临床应用方面不劣于跨国制造的设备。其优点是便携、成本较低且易于使用,这使得该设备更适合家庭眼部护理。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e8fa/12001302/4e6fac61cd5d/cureus-0017-00000080711-i01.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验