Suppr超能文献

使用CIRCLE软件在角膜透镜取出术后进行强化以实现高级屈光矫正。

Enhancement using CIRCLE software post cornea lenticule extraction for advanced refractive correction.

作者信息

Sachdev Gitansha S, Neemuchwala Tasneem, Ramamurthy Shreyas

机构信息

Refractive Services, The Eye Foundation, Coimbatore, Tamil Nadu, India.

出版信息

Indian J Ophthalmol. 2025 Jul 1;73(7):1012-1015. doi: 10.4103/IJO.IJO_2186_24. Epub 2025 Apr 17.

Abstract

PURPOSE

To report visual outcomes of enhancement after corneal lenticular extraction for advanced refractive correction (CLEAR, Femto LDV) using the CIRCLE software (Carl Zeiss Meditec, Germany).

METHODS

A prospective interventional study included eyes undergoing enhancement for under-correction or regression following CLEAR; at least three months after the primary procedure. CIRCLE software (pattern D) was used to convert the initial cap into a flap, which was subsequently raised and the stromal bed was ablated using an excimer laser (Zeiss Mel 90), with a Plano target in all eyes. Safety and visual outcomes at the three months postoperative visit were analyzed, with maximum follow-up till one year.

RESULTS

Nine eyes of six patients were included in the data analysis. The mean preoperative refractive spherical equivalent treated using the CLEAR software was -5.04 ± 2.28 diopter (D). Enhancement was performed for a mean residual error of -0.86 ± 0.54 D. The CIRCLE procedure was performed 6.67 ± 1.79 months after the primary procedure and resulted in a final manifest spherical equivalent of - 0.01 ± 0.04 D at the three months postoperative visit ( P = 0.001867). Mean uncorrected distance visual acuity (UDVA) improved from logMAR 0.31 ± 0.11 to 0.01 ± 0.03 ( P = 0.0008). Post-enhancement UDVA of 20/20 or better was achieved in 78% of the eyes. None of the eyes reported loss of lines in corrected distance visual acuity (CDVA). No intraoperative complications were noted in the cohort. No incidence of epithelial ingrowth, regression, or stromal haze was noted up till one year postoperative visit.

CONCLUSION

CIRCLE software may be considered as an optional treatment modality for enhancement following CLEAR.

摘要

目的

报告使用CIRCLE软件(德国卡尔蔡司医疗科技公司)对晚期屈光不正矫正(CLEAR,飞秒LDV)进行角膜透镜摘除术后的视力改善情况。

方法

一项前瞻性干预性研究纳入了因CLEAR术后欠矫或回退而接受增效治疗的眼睛;初次手术后至少三个月。使用CIRCLE软件(模式D)将初始角膜瓣转换为一个瓣片,随后掀起该瓣片,并用准分子激光(蔡司Mel 90)对基质床进行消融,所有眼睛均设定为平光目标。分析术后三个月随访时的安全性和视力改善情况,最长随访期至一年。

结果

数据分析纳入了6例患者的9只眼睛。使用CLEAR软件治疗的术前平均等效球镜度为-5.04±2.28屈光度(D)。增效治疗的平均残余误差为-0.86±0.54 D。CIRCLE手术在初次手术后6.67±1.79个月进行,术后三个月随访时最终等效球镜度为-0.01±0.04 D(P = 0.001867)。平均未矫正远视力(UDVA)从logMAR 0.31±0.11提高到0.01±0.03(P = 0.0008)。78%的眼睛增效治疗后的UDVA达到20/20或更好。所有眼睛均未出现矫正远视力(CDVA)下降。该队列中未观察到术中并发症。直至术后一年随访,未发现上皮内生、回退或基质 haze 的发生。

结论

CIRCLE软件可被视为CLEAR术后增效治疗的一种可选治疗方式。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验