Küppers Fabian, Kassem Mohamed, Yun Seong Dae, Stoffels Gabriele, Filß Christian, Galldiks Norbert, Mottaghy Felix M, Kooi M Eline, Langen Karl-Josef, Lohmann Philipp, Shah N Jon
Institute of Neuroscience and Medicine 4, Forschungszentrum Jülich, Jülich, Germany.
Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, the Netherlands.
J Magn Reson Imaging. 2025 Sep;62(3):721-736. doi: 10.1002/jmri.29795. Epub 2025 Apr 17.
Tumor characterization and treatment efficacy are associated with tissue hypoxia. MR-derived oxygen extraction fraction (OEF) may offer valuable tumor insights but depends on multiple measurement parameters, often requiring multiple sequence acquisitions. Specific multi-parametric sequences offer direct access to MR parameter sets within short acquisition times.
To evaluate the potential of gradient-echo spin-echo echo-planar imaging with keyhole (GE-SE EPIK)-derived parameters (OEF/T/T*/venous cerebral blood volume (vCBV)) to characterize increased metabolic activity tissue identified in [F]fluoroethyl-L-tyrosine (FET) PET, serving as a surrogate for neoplastic tissue.
Retrospective.
Fifty-seven brain tumor patients (female/male:31/26; age 27-73 years) with 66 histologically confirmed lesions (suspected glioblastoma (16), glioblastoma (28), astrocytoma (11), metastasis (6), oligodendroglioma (5)).
FIELD STRENGTH/SEQUENCE: 10-echo GE-SE EPIK sequence at 3 T.
GE-SE EPIK data were acquired in a hybrid MR PET scanner during FET PET acquisitions. Two tumor segmentations based on FET-PET uptake and FLAIR hyperintensities were manually created. Mean GE-SE EPIK-derived parameters were calculated within tumor regions and compared to contralateral reference values. Relative tumor-to-reference parameters were compared across tumor types.
One/two-sampled, two-tailed t-tests of mean relative MR-derived parameters. p-value < 0.05 was considered significant.
Significantly increased T/T* and decreased vCBV/OEF were found in FET-PET and FLAIR-derived VOIs. Latter showed decreased R2'. Significant correlation between FET uptake and T/T* was found in FET-VOIs (Pearson correlation: 0.26/0.31, respectively). Oligodendrogliomas showed significant differences to glioblastomas (rR', rOEF) and astrocytomas (rR'). Metastasis showed different rT values than suspected gliomas. Astrocytoma differed from gliomas in FET-TBR. Susceptibility artifacts in T* maps from air-tissue interfaces limited qualitative data interpretation.
GE-SE EPIK provides multiple MR parameters that are sensitive to expected changes in tumor regions obtained from FET and FLAIR thresholds. Susceptibility artifacts in T*/OEF maps made the differentiation between tumor relapse and treatment-related changes challenging. However, certain MR-derived parameters showed the ability to distinguish tumor types.
Stage 2.
肿瘤特征及治疗效果与组织缺氧相关。磁共振成像衍生的氧摄取分数(OEF)可能为肿瘤提供有价值的见解,但它取决于多个测量参数,通常需要采集多个序列。特定的多参数序列可在短采集时间内直接获取磁共振参数集。
评估基于锁孔梯度回波自旋回波平面成像(GE-SE EPIK)衍生参数(OEF/T/T*/脑静脉血容量(vCBV))对[F]氟乙基-L-酪氨酸(FET)PET中确定的代谢活性增加组织(作为肿瘤组织的替代物)进行特征描述的潜力。
回顾性研究。
57例脑肿瘤患者(女性/男性:31/26;年龄27 - 73岁),有66个经组织学证实的病变(疑似胶质母细胞瘤(16例)、胶质母细胞瘤(28例)、星形细胞瘤(11例)、转移瘤(6例)、少突胶质细胞瘤(5例))。
场强/序列:3T下的10回波GE-SE EPIK序列。
在FET PET采集期间,于混合磁共振PET扫描仪中采集GE-SE EPIK数据。基于FET-PET摄取和液体衰减反转恢复(FLAIR)高信号手动创建了两个肿瘤分割区域。计算肿瘤区域内GE-SE EPIK衍生参数的平均值,并与对侧参考值进行比较。比较不同肿瘤类型的肿瘤与参考参数的相对值。
对平均相对磁共振衍生参数进行单/双样本、双尾t检验。p值<0.05被认为具有统计学意义。
在FET-PET和FLAIR衍生的感兴趣区(VOI)中发现T/T显著升高,vCBV/OEF降低。后者显示R2'降低。在FET-VOI中发现FET摄取与T/T之间存在显著相关性(Pearson相关性分别为0.26/0.31)。少突胶质细胞瘤与胶质母细胞瘤(rR'、rOEF)和星形细胞瘤(rR')存在显著差异。转移瘤的rT值与疑似胶质瘤不同。星形细胞瘤在FET肿瘤-本底比值(TBR)方面与胶质瘤不同。气-组织界面T*图中的敏感性伪影限制了定性数据的解释。
GE-SE EPIK提供了多个对从FET和FLAIR阈值获得的肿瘤区域预期变化敏感的磁共振参数。T*/OEF图中的敏感性伪影使得区分肿瘤复发和治疗相关变化具有挑战性。然而,某些磁共振衍生参数显示出区分肿瘤类型的能力。
3级。
2级。