Suppr超能文献

高阶非球面单焦点人工晶状体与标准人工晶状体之间的视力和光学质量比较。

Comparison of visual acuity and optical quality between higher-order aspheric monofocal and standard introcular lenses.

作者信息

Janekova Andrea, Polachova Martina, Piñero David P, Studeny Pavel

机构信息

Department of Ophthalmology, University Hospital Královské Vinohrady and 3rd Faculty of Medicine, Charles University, Prague 10034, Czech Republic.

Faculty of Medicine, Charles University Hradec Kralove, Hradec Kralove 50003, Czech Republic.

出版信息

Int J Ophthalmol. 2025 Apr 18;18(4):598-605. doi: 10.18240/ijo.2025.04.05. eCollection 2025.

Abstract

AIM

To compare the 12-month outcomes of visual performance and patient satisfaction of a higher-order aspheric monofocal intraocular lens (IOL) and a conventional monofocal IOL.

METHODS

Prospective, randomized, comparative, double-blinded study including 22 patients who underwent bilateral cataract surgery with implantation of the Tecnis Eyhance ICB00 IOL in one eye (ICB00 group) and the Tecnis ZCB00 IOL in the fellow eye (ZCB00 group). Uncorrected distance (UDVA), corrected distance (CDVA), uncorrected intermediate (UIVA), distance-corrected intermediate (DCIVA), uncorrected near (UNVA), and distance-corrected near visual acuities (DCNVA) were evaluated during a 12-month follow-up. Contrast sensitivity, defocus curves, and reading text size were also evaluated. Patient satisfaction was assessed with a questionnaire at the 6-month postoperative visit.

RESULTS

Mean postoperative logMAR UDVA was 0.01±0.12 and -0.02±0.10 in ICB00 and ZCB00 groups, respectively (=0.37). Mean logMAR UIVA was 0.32±0.19 and 0.45±0.16 in ICB00 and ZCB00 groups, respectively (=0.010). Differences between groups in UNVA did not reach statistical significance (=0.16). The intermediate reading acuity at 66 cm (=0.02) and 80 cm (=0.04) was significantly better in the ICB00 group. Postoperative contrast sensitivity results did not differ significantly between groups (>0.05). Patients reported high overall satisfaction, with 62% of patients using spectacles for reading in everyday life.

CONCLUSION

The eyes of patients implanted with the enhanced monofocal IOL evaluated have significantly better visual acuity for intermediate distances with the same contrast sensitivity as a conventional monofocal IOL.

摘要

目的

比较高阶非球面单焦点人工晶状体(IOL)与传统单焦点IOL在12个月时的视觉性能和患者满意度结果。

方法

前瞻性、随机、对照、双盲研究,纳入22例接受双侧白内障手术的患者,一只眼植入Tecnis Eyhance ICB00 IOL(ICB00组),另一只眼植入Tecnis ZCB00 IOL(ZCB00组)。在12个月的随访期间评估未矫正远视力(UDVA)、矫正远视力(CDVA)、未矫正中视力(UIVA)、远矫正中视力(DCIVA)、未矫正近视力(UNVA)和远矫正近视力(DCNVA)。还评估了对比敏感度、散焦曲线和阅读字体大小。在术后6个月随访时通过问卷调查评估患者满意度。

结果

ICB00组和ZCB00组术后平均logMAR UDVA分别为0.01±0.12和 -0.02±0.10(P = 0.37)。ICB00组和ZCB00组平均logMAR UIVA分别为0.32±0.19和0.45±0.16(P = 0.010)。两组间UNVA差异无统计学意义(P = 0.16)。ICB00组在66 cm(P = 0.02)和80 cm(P = 0.04)处的中间阅读视力明显更好。术后两组对比敏感度结果差异无统计学意义(P>0.05)。患者总体满意度较高,62%的患者在日常生活中使用眼镜阅读。

结论

与传统单焦点IOL相比,植入评估的增强型单焦点IOL的患者眼睛在中等距离处具有明显更好的视力,且对比敏感度相同。

相似文献

1
Comparison of visual acuity and optical quality between higher-order aspheric monofocal and standard introcular lenses.
Int J Ophthalmol. 2025 Apr 18;18(4):598-605. doi: 10.18240/ijo.2025.04.05. eCollection 2025.
2
Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses.
Indian J Ophthalmol. 2024 Feb 1;72(2):181-184. doi: 10.4103/IJO.IJO_681_23. Epub 2024 Jan 25.
4
Comparative Analysis of Clinical and Patient-Reported Outcomes of a New Enhanced Monofocal IOL and a Conventional Monofocal IOL.
Clin Ophthalmol. 2024 May 1;18:1157-1169. doi: 10.2147/OPTH.S456332. eCollection 2024.
5
Comparison of an aspheric monofocal intraocular lens with the new generation monofocal lens using defocus curve.
Indian J Ophthalmol. 2020 Dec;68(12):3025-3029. doi: 10.4103/ijo.IJO_985_20.
7
Clinical outcomes with an aspheric monofocal and a new enhanced monofocal intraocular lens with modified optical profile.
Graefes Arch Clin Exp Ophthalmol. 2023 Aug;261(8):2315-2326. doi: 10.1007/s00417-023-06128-8. Epub 2023 May 31.
9
Intraindividual Comparison of an Enhanced Monofocal and an Aspheric Monofocal Intraocular Lens of the Same Platform.
Am J Ophthalmol. 2024 May;261:95-102. doi: 10.1016/j.ajo.2023.11.006. Epub 2023 Nov 8.

本文引用的文献

2
Quality of vision clinical outcomes for a new fully-refractive extended depth of focus Intraocular Lens.
Eye (Lond). 2024 May;38(Suppl 1):9-14. doi: 10.1038/s41433-024-03039-8. Epub 2024 Apr 5.
4
Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses.
Indian J Ophthalmol. 2024 Feb 1;72(2):181-184. doi: 10.4103/IJO.IJO_681_23. Epub 2024 Jan 25.
5
Clinical Results and Factors Affecting Visual Function in Eyes Implanted with an Enhanced Monofocal Intraocular Lens.
Clin Ophthalmol. 2023 Dec 21;17:3965-3973. doi: 10.2147/OPTH.S438599. eCollection 2023.
9
Clinical outcomes with an aspheric monofocal and a new enhanced monofocal intraocular lens with modified optical profile.
Graefes Arch Clin Exp Ophthalmol. 2023 Aug;261(8):2315-2326. doi: 10.1007/s00417-023-06128-8. Epub 2023 May 31.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验