Fitchett M A
Br J Sports Med. 1985 Jun;19(2):85-8. doi: 10.1136/bjsm.19.2.85.
The predictability of the maximal oxygen uptake (VO2 max) was studied using progressive and steady state protocols for cycle ergometry and bench stepping. The subjects were 12 healthy men, 23-58 years old. Prediction of VO2 max was made by extrapolation of the heart rate and O2 uptake at several sub-maximal work-loads using the least squares regression technique. The four sub-maximal procedures underestimated the measured VO2 max by between 0.13-0.55 l.min-1. The differences between the measured and predicted values were statistically significant for the tests involving the steady state protocol. The correlation coefficients between the predicted VO2 max for each of the submaximal tests, and the measured VO2 max, were significant at the .05 level. The results indicate that for a group of male subjects VO2 max can be predicted using the progressive protocol on either the cycle ergometer or stepping bench. Individual predictions are liable to considerable error.
使用递增和稳态方案进行自行车测功和台阶试验,研究了最大摄氧量(VO2 max)的可预测性。受试者为12名年龄在23至58岁之间的健康男性。通过使用最小二乘法回归技术,对几个次最大工作量下的心率和摄氧量进行外推,来预测VO2 max。四种次最大测试程序将测得的VO2 max低估了0.13至0.55升·分钟-1。对于涉及稳态方案的测试,测量值与预测值之间的差异具有统计学意义。每个次最大测试的预测VO2 max与测得的VO2 max之间的相关系数在0.05水平上具有显著性。结果表明,对于一组男性受试者,可以使用自行车测力计或台阶试验台上的递增方案来预测VO2 max。个体预测容易出现相当大的误差。