立体摄影测量技术与口腔内扫描仪用于全牙弓种植体数字化印模的准确性:一项系统评价与Meta分析

Accuracy of Stereophotogrammetry Technique versus Intraoral Scanners for Complete-Arch Implant Digital Impressions: A Systematic Review and Meta-Analysis.

作者信息

Jain Saurabh, Daak Huda Ali, Someli Lena Abdulrahman, Alamer Amwaj Yahya, Apratim Abhishek, Akoor Ruaa Mohammed Ali, Ayoub Mohammed

机构信息

Department of Prosthetic Dental Sciences, College of Dentistry, Jazan University, Jazan, Saudi Arabia.

College of Dentistry, Jazan University, Jazan, Saudi Arabia.

出版信息

Eur J Dent. 2025 May 1. doi: 10.1055/s-0045-1806935.

Abstract

This systematic literature review aimed to evaluate the accuracy of the stereophotogrammetry based dental scanners in determining complete-arch implant retained prosthesis compared to intraoral scanners (IOSs). The focused PICO (Population, Intervention, Comparison, Outcome) directed was "Do complete arch implant (P) impressions made using stereophotogrammetry-based dental scanners (I) have the same accuracy (O) when compared to impressions made using IOS (C)?" Recommendations listed by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) were used for structuring and reporting this review. This systematic review and meta-analysis was preregistered in the International Prospective Register of Systematic Reviews (PROSPERO) bearing the registration number CRD42024597913. To search the relevant titles, four electronic databases (MEDLINE/PubMed, Scopus, Cochrane Library, and Web of Science) were systematically searched in October 2024. The inclusion criteria include research papers published up to September 2024 in English comparing the accuracy of stereophotogrammetry-based dental scanners with IOS in recording the impression of complete-arch implants. Studies conducted on animals were excluded. Also excluded were unpublished reports, theses and dissertations, and case reports. After the initial search of the selected databases, a total of 590 titles were identified. The synthesis included 13 articles for qualitative analysis, but only 8 provided comparative data for quantitative analysis, which was performed using review manager (RevMan) Version 5.4. in non-Cochrane mode. The Modified CONSORT scale was used for quality and risk-of-bias assessment, while the QUADAS-2 tool was utilized for studies. The systematic review and meta-analysis reveals that stereophotogrammetric-based dental scanners offer higher accuracy in recording complete-arch implant-supported prosthesis impressions compared to IOS. The current review and meta-analysis compared of the accuracy of stereophotogrammetry-based dental scanners with IOSs. Limitations include medium to high quality of selected studies, with most of the studies displaying a high risk of bias, high heterogeneity in the control groups, and generalizability concerns. Accuracy of dental implant impressions is influenced by the type of scanner used for scanning. Stereophotogrammetry-based dental scanners are more accurate than IOS.

摘要

本系统文献综述旨在评估基于立体摄影测量的牙科扫描仪在确定全牙弓种植体固位修复体方面相对于口内扫描仪(IOS)的准确性。聚焦的PICO(人群、干预措施、对照、结局)为“与使用IOS制作的印模相比,使用基于立体摄影测量的牙科扫描仪制作的全牙弓种植体(P)印模在准确性(O)方面是否相同(C)?”本综述的构建和报告采用了系统评价和Meta分析的首选报告项目(PRISMA)列出的建议。本系统评价和Meta分析已在国际系统评价前瞻性注册库(PROSPERO)中预注册,注册号为CRD42024597913。为检索相关标题,于2024年10月对四个电子数据库(MEDLINE/PubMed、Scopus、Cochrane图书馆和Web of Science)进行了系统检索。纳入标准包括截至2024年9月以英文发表的比较基于立体摄影测量的牙科扫描仪与IOS在记录全牙弓种植体印模准确性方面的研究论文。排除在动物身上进行的研究。未发表的报告、论文和学位论文以及病例报告也被排除。在对选定数据库进行初步检索后,共识别出590个标题。综合分析包括13篇用于定性分析的文章,但只有8篇提供了用于定量分析的比较数据,定量分析使用Review Manager(RevMan)5.4版本在非Cochrane模式下进行。改良的CONSORT量表用于质量和偏倚风险评估,而QUADAS - 2工具用于研究。该系统评价和Meta分析表明,与IOS相比,基于立体摄影测量的牙科扫描仪在记录全牙弓种植体支持修复体印模方面具有更高的准确性。当前的综述和Meta分析比较了基于立体摄影测量的牙科扫描仪与IOS的准确性。局限性包括所选研究质量为中等至高,大多数研究显示出高偏倚风险、对照组中高度异质性以及普遍性问题。牙科种植体印模的准确性受用于扫描的扫描仪类型影响。基于立体摄影测量的牙科扫描仪比IOS更准确。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验