Suppr超能文献

短/超短回波时间磁共振成像序列在犬类颅骨成像中与计算机断层扫描相当且优于标准磁共振成像序列。

Short/Ultra-Short TE MRI Sequences Comparable to CT and Superior to Standard MRI Sequences for Canine Skull Imaging.

作者信息

Cicci Maura C, Keenihan Erin K, Bailey Kate, Graham Lynelle, Sommer Stefan, Cohen Eli B

机构信息

Red Bank Veterinary Hospital, Tinton Falls, New Jersey, USA.

Department of Molecular Biomedical Sciences, College of Veterinary Medicine, NC State University, Raleigh, North Carolina, USA.

出版信息

Vet Radiol Ultrasound. 2025 May;66(3):e70035. doi: 10.1111/vru.70035.

Abstract

Magnetic resonance imaging often needs to be complemented with CT for complete assessment of bony structures due to CTs increased spatial resolution and discrimination of cortical bone margins. The aims of this prospective method comparison study were to perform qualitative and quantitative comparisons of standard MR sequences with three short/ultra-short TE MR sequences using CT as the gold standard. Eight healthy research dogs of similar size had CT and MR of the head performed. Three short/ultra-short TE sequences, VIBE, PETRA, and UTE, alongside standard T2W, PD, and T1W TSE sequences of the head were obtained. Slice thickness of CT and short TE MR sequences were matched. A qualitative scale was used to assess the visibility of cortical margins and skull foramina. For the quantitative assessment, predetermined osseous structures and foramina on designated slices were measured. Levene's test and post hoc folded F tests with false discovery rate adjustments were applied to the residuals from these models to compare precision relative to CT across the sequence types. The short/ultra-short TE MR sequences were significantly better than the standard MR sequences for quantitative assessment of bone thickness of smaller structures and overall qualitative assessment. Any of these short/ultra-short TE sequences may be viable to incorporate into a clinical setting as an alternative to CT to help further evaluate the skull and reduce anesthesia time and client cost. VIBE, PETRA, and UTE sequences have diagnostic image quality and provide a consistent quantitative and qualitative assessment of the cortical bone of the skull when compared with CT.

摘要

由于CT具有更高的空间分辨率以及对皮质骨边缘的分辨能力,磁共振成像通常需要与CT互补,以全面评估骨结构。这项前瞻性方法比较研究的目的是以CT作为金标准,对标准MR序列与三种短/超短TE MR序列进行定性和定量比较。八只体型相似的健康实验犬接受了头部的CT和MR检查。获得了三种短/超短TE序列(VIBE、PETRA和UTE)以及头部标准的T2W、PD和T1W TSE序列。CT和短TE MR序列的切片厚度相匹配。使用定性量表评估皮质边缘和颅骨孔的可见性。对于定量评估,测量指定切片上预先确定的骨结构和孔。将Levene检验和经过错误发现率调整的事后折叠F检验应用于这些模型的残差,以比较不同序列类型相对于CT的精度。短/超短TE MR序列在对较小结构的骨厚度进行定量评估和整体定性评估方面明显优于标准MR序列。这些短/超短TE序列中的任何一种都可以作为CT的替代方法纳入临床环境,以帮助进一步评估颅骨,减少麻醉时间和客户成本。与CT相比,VIBE、PETRA和UTE序列具有诊断图像质量,并能对头骨皮质骨进行一致的定量和定性评估。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/93fe/12048040/a1918da96e5e/VRU-66-0-g006.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验