Ross P G, Sharp P F, Undrill P E
J Nucl Med. 1985 Sep;26(9):1081-4.
The evaluation is carried out of a simple filtering routine for improving the detectability of low contrast lesions in bone scans. With this routine, the unprocessed image is displayed together with three filtered versions, the final decision on the presence of abnormalities being made by comparing the four images. Emphasis is placed on producing a routine which is quick in implementation and, therefore, only small filter arrays are used. Using a routine consisting of a low-pass, a median, and a differential filter, 73% more lesions are detected when the filtered images are also used. The whole routine takes less than 1 min to run.
对一种用于提高骨扫描中低对比度病变可检测性的简单滤波程序进行了评估。通过该程序,未处理的图像与三个滤波版本一起显示,通过比较这四张图像来最终判定是否存在异常。重点在于生成一种实施速度快的程序,因此仅使用了小的滤波器阵列。使用由低通、中值和微分滤波器组成的程序,当也使用滤波后的图像时,检测到的病变数量增加了73%。整个程序运行时间不到1分钟。