Suppr超能文献

具有同心圆柱环形折射元件的透镜的实验与建模分析:对周边成像的影响

Experimental and modeling analysis of lenses with concentric cylindrical annular refractive elements: impact on peripheral imaging.

作者信息

Liu Yongji, Liu Dongyu, Hu Xiaoyang, Chen Xiaoqin, Liu Hongliang, Li Lihua

机构信息

Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Institute of Modern Optics, Nankai University, 38 Tongyan Road, Haihe Education Park, Tianjin 300350, China.

Institute of Optometry & Vision Science, Nankai University, 94 Weijin Road, Nankai District, Tianjin 300071, China.

出版信息

Biomed Opt Express. 2025 Mar 7;16(4):1344-1358. doi: 10.1364/BOE.546942. eCollection 2025 Apr 1.

Abstract

The mechanism by which myopia-managing spectacle lenses slow myopia progression remains controversial. Understanding the changes these lenses introduce to peripheral imaging properties helps shed light on this controversial issue. Given the difficulty of directly measuring these changes in clinical settings, this study combined experimental and modeling approaches to evaluate changes in images at the retina induced by myopia-managing lenses. Optical characteristics that may related to the efficacy of the lenses with concentric cylindrical annular refractive elements (CARE) in myopia control were investigated. Three lenses were evaluated: MyoCare (MC), MyoCare S (MCS), and a single vision (SV) lens with a custom-built physical eye model and optical simulations for the analysis. The simulated PSFs are consistent with the measured ones. PSF analysis showed that MC and MCS lenses produce discrete curves, resulting in remarkable distortion in the simulated retina images, especially for large eccentricities. Whether they increase or decrease contrast depends on the spatial frequencies and eccentricities. These lenses also increase retinal light intensity at different eccentricities. The positive power of the CARE structure introduces myopic defocus of less than 0.25 D at only a limited range of eccentricities. The proposed approaches present relatively straightforward techniques for evaluating the optical performance of myopia-managing spectacle lenses.

摘要

控制近视的眼镜镜片减缓近视进展的机制仍存在争议。了解这些镜片对周边成像特性所带来的变化,有助于阐明这一有争议的问题。鉴于在临床环境中直接测量这些变化存在困难,本研究结合实验和建模方法,以评估控制近视的镜片在视网膜上引起的图像变化。研究了可能与具有同心圆柱环形折射元件(CARE)的镜片在近视控制方面的效果相关的光学特性。评估了三种镜片:MyoCare(MC)、MyoCare S(MCS)以及一款单焦点(SV)镜片,采用定制的物理眼模型和光学模拟进行分析。模拟的点扩散函数(PSF)与测量结果一致。PSF分析表明,MC和MCS镜片产生离散曲线,导致模拟视网膜图像出现明显畸变,尤其是在较大偏心率时。它们是增加还是降低对比度取决于空间频率和偏心率。这些镜片还会在不同偏心率下增加视网膜光强度。CARE结构的正焦度仅在有限的偏心率范围内引入小于0.25 D的近视性离焦。所提出的方法为评估控制近视的眼镜镜片的光学性能提供了相对直接的技术。