Suppr超能文献

以关节镜检查作为参考标准,7T和3T下腕部韧带损伤的MRI表现相似。

MRI of wrist ligament trauma was similar at 7 T and 3 T with arthroscopy as a reference standard.

作者信息

Götestrand Simon, Flondell Magnus, Lundin Björn, Aksyuk Elena, Shalhoub Rami Abu, Szaro Pawel, Hedström Erik, Björkman Anders, Geijer Mats

机构信息

Diagnostic Radiology, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.

Department of Radiology, Skåne University Hospital, Lund, Sweden.

出版信息

Eur Radiol. 2025 May 8. doi: 10.1007/s00330-025-11656-4.

Abstract

OBJECTIVES

The aim was to compare the diagnostic accuracy of magnetic resonance imaging (MRI) at 7 Tesla (T) and 3 T in patients with clinically suspected injury of the triangular fibrocartilage complex (TFCC) or the scapholunate ligament (SLL) using wrist arthroscopy as a reference standard.

METHODS

Twenty-four patients scheduled for wrist arthroscopy due to suspected TFCC or SLL injury were examined with 7-T and 3-T MRI before arthroscopy. Four musculoskeletal radiologists independently evaluated the MR examinations in randomized order, and the findings were compared to those at wrist arthroscopy.

RESULTS

Sensitivity, specificity, and accuracy for TFCC injuries were 0.85, 0.68, and 0.82 for 7 T and 0.75, 0.73, and 0.77 for 3 T, respectively. For SLL injuries, the corresponding values were 0.70, 0.65, and 0.74 for 7 T and 0.69, 0.55, and 0.70 for 3 T, respectively. For both TFCC and SLL injuries, no statistically significant difference between 7 T and 3 T was found, and the confidence intervals for accuracy overlapped (0.67-0.94 vs 0.63-0.88 for TFCC injuries and 0.59-0.89 vs 0.52-0.86 for SLL injuries). In 14 of 24 patients (58%), MRI contributed findings of additional types of injuries, e.g., tendon injuries and ganglia, vital for a complete diagnosis.

CONCLUSIONS

The diagnostic accuracy of MRI at 7 T was similar to 3 T for detecting injury to the TFCC and the SLL. A majority of injuries were correctly diagnosed by MRI, but some injuries found using arthroscopy were missed.

KEY POINTS

Question Previous studies have found that MRI cannot reliably diagnose or rule out TFCC or SLL injury, compared to the current reference standard wrist arthroscopy. Findings The diagnostic accuracy for MRI at 7 T was similar to 3 T for detecting injuries to the TFCC and the SLL. Clinical relevance Although MRI cannot replace wrist arthroscopy, it is an important complementary tool in the diagnostic workup of suspected wrist ligament injuries, with the ability to diagnose additional types of pathologies not accessible by arthroscopy.

摘要

目的

本研究旨在以腕关节镜检查作为参考标准,比较7特斯拉(T)和3T磁共振成像(MRI)对临床疑似三角纤维软骨复合体(TFCC)或舟月韧带(SLL)损伤患者的诊断准确性。

方法

24例因疑似TFCC或SLL损伤而计划进行腕关节镜检查的患者,在关节镜检查前接受了7T和3T MRI检查。4名肌肉骨骼放射科医生以随机顺序独立评估MR检查结果,并将其与腕关节镜检查结果进行比较。

结果

对于TFCC损伤,7T时的敏感性、特异性和准确性分别为0.85、0.68和0.82,3T时分别为0.75、0.73和0.77。对于SLL损伤,7T时相应的值分别为0.70、0.65和0.74,3T时分别为0.69、0.55和0.70。对于TFCC和SLL损伤,7T和3T之间均未发现统计学上的显著差异,准确性的置信区间重叠(TFCC损伤为0.67 - 0.94 vs 0.63 - 0.88,SLL损伤为0.59 - 0.89 vs 0.52 - 0.86)。在24例患者中的14例(58%)中,MRI发现了其他类型的损伤,如肌腱损伤和腱鞘囊肿,这些对完整诊断至关重要。

结论

7T MRI对TFCC和SLL损伤的诊断准确性与3T相似。大多数损伤通过MRI被正确诊断,但一些关节镜检查发现的损伤被遗漏。

关键点

问题 以往研究发现,与当前参考标准腕关节镜检查相比,MRI不能可靠地诊断或排除TFCC或SLL损伤。发现 7T MRI对TFCC和SLL损伤的诊断准确性与3T相似。临床意义 虽然MRI不能替代腕关节镜检查,但它是疑似腕关节韧带损伤诊断检查中的重要辅助工具,能够诊断关节镜检查无法发现的其他类型病变。