Kastrup J, Feldt-Rasmussen U, Bartram H R, Witten J, Sand Hansen H
Scand J Clin Lab Invest. 1985 Sep;45(5):471-6. doi: 10.3109/00365518509155245.
The aim of the study was to develop an enzyme linked immunosorbent assay (ELISA) for measuring thyroglobulin (Tg) in human serum and to evaluate the influence of serum thyroglobulin auto-antibodies (TgAb) on the ELISA. The sensitivity of the ELISA was 2.1 micrograms/l. Serum Tg levels in healthy controls were from less than 2.1 to 55.5 micrograms/l (n = 46) (95% reference range). With serum Tg concentrations between 19.6 to 90 micrograms/l the within-assay coefficient of variation (CV) was from 4.5 to 6.6% (n = 12) and the between-assay CV from 8.5 to 10.5% (n = 6). The recovery from 20 to 89 micrograms Tg/l serum was from 93 to 101%. There was significant correlation between serum Tg concentrations measured by the ELISA and a RIA method in healthy controls (r = 0.85, n = 46, p less than 0.001) and in patients with differentiated thyroid carcinoma (r = 0.97, n = 28, p less than 0.001). The TgAb interfered with the serum Tg determination both in the ELISA and in the RIA method. The assay is simple and easy to perform, and the equipment is inexpensive and useful for large-scale serum Tg measurements as an alternative to RIA.
本研究的目的是开发一种用于检测人血清中甲状腺球蛋白(Tg)的酶联免疫吸附测定法(ELISA),并评估血清甲状腺球蛋白自身抗体(TgAb)对ELISA的影响。ELISA的灵敏度为2.1微克/升。健康对照者的血清Tg水平为低于2.1至55.5微克/升(n = 46)(95%参考范围)。当血清Tg浓度在19.6至90微克/升之间时,批内变异系数(CV)为4.5%至6.6%(n = 12),批间CV为8.5%至10.5%(n = 6)。血清中20至89微克Tg/升的回收率为93%至101%。在健康对照者中(r = 0.85,n = 46,p < 0.001)以及在分化型甲状腺癌患者中(r = 0.97,n = 28,p < 0.001),ELISA法和放射免疫分析法(RIA)测定的血清Tg浓度之间存在显著相关性。TgAb在ELISA法和RIA法中均干扰血清Tg的测定。该测定法操作简单,设备价格低廉,可作为RIA的替代方法用于大规模血清Tg检测。