Suppr超能文献

脊柱侧弯患者使用钴铬合金棒和钛合金棒进行器械脊柱融合术后血液中金属离子水平的比较。

Comparison of blood metal ion levels in scoliosis patients following instrumented spinal fusion with cobalt-chromium and titanium alloy rods.

作者信息

Tamagawa Shota, Nojiri Hidetoshi, Sato Tatsuya, Matsukawa Takehisa, Homma Yasuhiro, Takano Hiromitsu, Ishijima Muneaki

机构信息

Department of Orthopaedics, Juntendo University Faculty of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo, 113-8421, Japan.

Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan.

出版信息

Sci Rep. 2025 May 13;15(1):16549. doi: 10.1038/s41598-025-99065-x.

Abstract

Elevated blood metal ion levels have been reported in patients following instrumented spinal fusion. However, the relationship between blood metal ion levels and clinical and radiographic outcomes remains elusive. The purpose of this study was to compare blood metal ion levels in patients with scoliosis undergoing corrective fusion surgery utilizing either cobalt-chromium (CoCr) or titanium (Ti) alloy rods, as well as preoperative scoliosis patients. Additionally, we investigated patient- and surgery-related factors associated with blood metal ion levels. This retrospective cohort study included 59 patients with CoCr rods (CoCr group), 29 patients with Ti alloy rods (Ti group), and 17 preoperative patients (control group). Blood samples were collected at a mean of 63 months postoperatively for the CoCr group and 113 months postoperatively for the Ti group. Blood levels of Co, Cr, and Ti were measured by inductively coupled plasma mass spectrometry. Blood Co levels were significantly elevated in the CoCr group compared to the control group (p = 0.021), with no significant difference observed between the CoCr and Ti groups (CoCr group: 0.28 μg/L, Ti group: 0.21 μg/L, control group: 0.20 μg/L). However, blood Cr and Ti levels were found to be below the limit of quantification in all 105 individuals. Furthermore, a significant negative correlation was observed between blood Co levels and the postoperative follow-up duration. These findings underscore the medium-term safety rather than the concerns regarding blood metal ion levels following corrective fusion for scoliosis; however, prolonged and meticulous follow-up is imperative.

摘要

据报道,在接受脊柱内固定融合手术的患者中,血液金属离子水平会升高。然而,血液金属离子水平与临床和影像学结果之间的关系仍不明确。本研究的目的是比较使用钴铬(CoCr)合金棒或钛(Ti)合金棒进行矫正融合手术的脊柱侧弯患者以及术前脊柱侧弯患者的血液金属离子水平。此外,我们还研究了与血液金属离子水平相关的患者和手术相关因素。这项回顾性队列研究包括59例使用CoCr合金棒的患者(CoCr组)、29例使用Ti合金棒的患者(Ti组)和17例术前患者(对照组)。CoCr组在术后平均63个月采集血样,Ti组在术后113个月采集血样。通过电感耦合等离子体质谱法测量血液中Co、Cr和Ti的水平。与对照组相比,CoCr组的血液Co水平显著升高(p = 0.021),CoCr组和Ti组之间未观察到显著差异(CoCr组:0.28μg/L,Ti组:0.21μg/L,对照组:0.20μg/L)。然而,在所有105名个体中,血液Cr和Ti水平均低于定量限。此外,观察到血液Co水平与术后随访时间呈显著负相关。这些发现强调了脊柱侧弯矫正融合术后中期的安全性,而非对血液金属离子水平的担忧;然而,长期细致的随访是必不可少的。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3033/12075639/87030400d50b/41598_2025_99065_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验