Suppr超能文献

与单纯前后位螺钉固定相比,钢板增强固定粉碎性Letenneur II型Hoffa骨折具有更好的稳定性——一项生物力学研究。

Plate-augmented fixation of comminuted Letenneur type II Hoffa fractures provides favorable stability compared to isolated posteroanterior screw fixation - a biomechanical study.

作者信息

Peez Christian, Lodde Moritz F, Zderic Ivan, Richards R Geoff, Drenchev Ludmil, Skulev Hristo K, Gueorguiev Boyko, Kittl Christoph, Raschke Michael J, Herbst Elmar

机构信息

Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.

AO Research Institute, Davos, Switzerland.

出版信息

Arch Orthop Trauma Surg. 2025 May 19;145(1):301. doi: 10.1007/s00402-025-05920-x.

Abstract

INTRODUCTION

Current literature lacks recommendations regarding proper fixation of comminuted coronal plane fractures of the posterior femoral condyles (Hoffa fractures). Therefore, the aim of this study was to compare the biomechanical characteristics of different plate-augmented constructs to isolated posteroanterior screw fixation in comminuted lateral Hoffa fractures.

MATERIALS AND METHODS

Comminuted Letenneur type IIb lateral Hoffa fractures were simulated in 24 human cadaveric distal femora. The fractures were fixed with either isolated crossed posteroanterior screws or additionally with either a posterior plate, a lateral locking plate, or combined posterior and lateral locking plates. All specimens were biomechanically tested under progressively increasing cyclic loading until failure, while capturing the interfragmentary movements of the Hoffa and intercalary fragments via motion tracking.

RESULTS

Plate-augmented posteroanterior screw fixation of the Hoffa fragment exhibited higher cycles to failure, higher failure loads (p < 0.05) and less axial displacements (p < 0.05) compared to isolated posteroanterior screw fixation. Both additional lateral locking and double plate fixations of the intercalary fragment provided higher cycles to failure, higher failure loads (p < 0.05) and less axial displacement (p < 0.05) than isolated posteroanterior screw fixation, whereas additional posterior plate fixation did not significantly increase cycles to failure, failure loads and axial displacement (n.s.). Fracture gap twisting and opening did not differ significantly between the four constructs for the Hoffa fragment, while plate-augmented constructs provided less fracture opening of the intercalary fragment compared to isolated posteroanterior screw fixation (p < 0.01).

CONCLUSIONS

Plate-augmented posteroanterior screw fixation of comminuted Letenneur type IIb Hoffa fractures provided greater biomechanical stability than isolated posteroanterior screw fixation. While additional lateral or double plate fixation improves the stability of both the intercalary and Hoffa fragment, posterior plating stabilized only the Hoffa fragment.

摘要

引言

目前的文献缺乏关于股骨后髁冠状面粉碎性骨折(Hoffa骨折)恰当固定的建议。因此,本研究的目的是比较不同钢板增强结构与单纯前后位螺钉固定在外侧Hoffa粉碎性骨折中的生物力学特性。

材料与方法

在24具人类尸体股骨远端模拟Letenneur IIb型外侧Hoffa粉碎性骨折。骨折采用单纯交叉前后位螺钉固定,或额外使用后钢板、外侧锁定钢板或后外侧联合锁定钢板固定。所有标本在循环载荷逐渐增加直至失效的情况下进行生物力学测试,同时通过运动跟踪捕捉Hoffa骨折块和中间骨折块的骨折块间运动。

结果

与单纯前后位螺钉固定相比,Hoffa骨折块采用钢板增强的前后位螺钉固定表现出更高的失效循环次数、更高的失效载荷(p < 0.05)和更小的轴向位移(p < 0.05)。中间骨折块额外的外侧锁定和双钢板固定均比单纯前后位螺钉固定提供了更高的失效循环次数、更高的失效载荷(p < 0.05)和更小的轴向位移(p < 0.05),而额外的后钢板固定并未显著增加失效循环次数、失效载荷和轴向位移(无统计学差异)。Hoffa骨折块的四种固定结构之间骨折间隙扭转和张开无显著差异,而与单纯前后位螺钉固定相比,钢板增强结构使中间骨折块的骨折张开更小(p < 0.01)。

结论

Letenneur IIb型Hoffa粉碎性骨折采用钢板增强的前后位螺钉固定比单纯前后位螺钉固定具有更高的生物力学稳定性。额外的外侧或双钢板固定可提高中间骨折块和Hoffa骨折块的稳定性,而后钢板固定仅稳定Hoffa骨折块。